background image

Max. weight of gate

200 Kg

Max. width of gate

2,50 mt

Motors power supply

24Vdc

230 Vac

Motor power

50 W

200 W

Motor RPM

1500

1400

Condenser

/

16 µF

Mechanical unlock for emergency manoeuvre

With key

Working temperature

-20° C / +55° C

weight

6.5 Kg

Protection rating

IP 55

Opening time 90°

15 sec

Rod stroke

300/400/500 mm

Force of thrust

1500 N

Motor current input

3 A

1 A

2

5

VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS

4

3

1

1

5

6

7

8

Optimal installation

1- Operator

2- External photocell

3- Flashing warning light

4-  Antenna

5- Internal photocell

6- Electronic control unit

7- Key-switch

8- Remote control

TECHNICAL DATA

Содержание PM1/SC

Страница 1: ...alling thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified pe...

Страница 2: ...TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 5 6 TROUBLESHOOTING 7 SAFETY PRECAUTIONS 8 PACKING CONTENTS 1 OPERATOR 1 KIT FASTEN...

Страница 3: ...erature 20 C 55 C weight 6 5 Kg Protection rating IP 55 Opening time 90 15 sec Rod stroke 300 400 500 mm Force of thrust 1500 N Motor current input 3 A 1 A 2 5 VIEW OF TYPICAL AUTOMATION AND NAMES OF...

Страница 4: ...TYPICAL CONNECTION AND CABLE SECTION 2X1 5mm2 24 Vdc 4X1 5mm2 230 Vca 2X0 75mm2 4X0 75mm2 4X0 75mm2 2X0 75mm2 3X1 5mm2 230V Line RX Photocell TX Photocell 280 mm 485 585 685 mm 88 mm 325 mm 88 mm 300...

Страница 5: ...sembling the automatism check that the gate is in perfect working order hangs well on its hinges and is suitably lubricated It must also comply with the safety standards in force in the country of ins...

Страница 6: ...opening 6 If positions correspond fix the plate on the gate otherwise revise A and B units table 1 Installing the anchor plate on the piston to the gate Release procedure To unblock the operator use...

Страница 7: ...or the beam is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote control the gate doesn t open but works with the key command The remote control...

Страница 8: ...s considered improper and therefore hazardous In addition the information given in this document and in the enclosed documentation may be subject to modifications without prior notice It is given as a...