vds EURO230M1 Скачать руководство пользователя страница 7

ALL DIP-SWITCH:

FEATURES

The control unit is EURO230M1 control equipment for sliding systems and road barriers to 230Vac power supply.
This panel can manage motors with or without limit switches, encoders and limitswitches.

The peculiarity of EURO230M1 is that it has separate torque control, through trimmer T1 and T2 (T1 regulates the torque while
running in normal speed the T2 adjusts the torque during deceleration)

. Interacting on these devices can optimize the operation of

the automation so as to be within the actual rules. The programming of the switches and remote controls is self-learning, so everything
is easier.

In case management through ENCODER (DIP 8 ON) security will be guaranteed by the photocells/bands safety or to torque
control: if the gate find an obstacle will be reversed or blocked.
With ENCODER not active (OFF DIP 8)

 not have the reverse function but only torque control through

trimmer

T1

 and

T2.

PROGRAMMING REMOTE CONTROL

The control unit is able to handle radio fixed code and rolling code. The two systems can not be managed simultaneously, but
with the first remote control will be programmed encoding system.

The EURO230M1 can handle 254 transmitters ROLLING CODE.
The programming of the transmitters is done by pressing the

P1 for 2sec

, the LED L2 turns on, then pressing the button of the remote

will flash twice to indicate the LED L2 is stored in memory. After 6 seconds automatically central will exit the programming function.

PROGRAMMING PEDESTRIAN MODE (by remote control)

To program this function push

P1 button for 2sec

,

 release it and press it again for 1 sec

, the LED L2 starts flashing and each press

of the button on a remote control will be a rapid double flash of the LED L2, after 6sec the control board automatically exit to
programming.

The operating time of the pedestrian mode is 8 sec.

REMOVE ALL CODES

Press and hold the

P1 for 6

seconds when it is released there will be a quick flash of the LED L2, with consequent turning off after 6

seconds.

PROGRAMMING THE STROKE

The programming begins automation is closed, the first operation will be the opening, otherwise reverse the direction by

DIP switch 4.

PROGRAMMING with slow down (DIP 7ON)

To enter in programming, press the P2 button for 2 seconds, the LED3 will flash

Give a

FIRST PULSE by START

 contact (terminals 1 and 2) or by transmitter already been programmed.

The operator will start the opening phase, give a

SECOND PULSE

 where you want to start the slow down in opening.

The engine will complete the stroke and will stop at close limitswitch (if you chose an automatism without limitswitches must give a
further impulse to fix the stopping point of the stroke).

If you choose to have the AUTOMATIC CLOSING (OPTION 2 IN ON), the closing time will be calculated from the moment when
the operator arrives to open limitswitch until you give the THIRD PULSE, the automatism will start closure.

Where do you want start slowing down in closing you must give the

FOURTH PULSE.

 The arrest will be through the closing limitswitch

and now the LED will turn off 3. If the automatism is not expected to limit switch, you will need to give a last pulse where you want
to stop.

PROGRAMMING without slow down (DIP 7OFF)

Set the option 7 to OFF for the exclusion of the slowdown phase. Follow the procedure listed above (learning with slowdown) without
transmitting the second pulse in opening and the fourth during closing. So once impulses transmitted to the beginning of the maneuvers,
in opening and in closing, they will finish at the limitswitch position.

OPERATION LOGIC OF THE SAFETY

SAFETY BAND TERMINAL (4-6)

   This contact protects opening and closing.

  

DIP 5 ON: in opening when there is an obstacle, the engine stop and reverse for 2 sec.

  

DIP 5 OFF: in opening when there is an obstacle engine STOP

  

In both cases in closing when there there is an obstacle the gate stop.

PHOTOCELLS TERMINAL (5-6)

    This contact protects only in closing

  

In closing when there is an obstacle engine STOP

STOP TERMINAL (18-19)

 

      

The contact if open will cause the immediate arrest of the automation in any situation.

DIP 1

COUNTERWEIGHT DOORS/SLIDING GATE

Counterweight doors function
Sliding gate function

DIP 2

AUTOMATIC CLOSING

Automatic closing activated
Automatic closing not actived

DIP 3

CONDOMINIUM / STEP BY STEP

The automation will end the operation always on end
switches, in opening does not accept pulses, in closing a
pulse will cause the reverse.
For each pulse automation will stop
(OPEN-STOP-CLOSE-STOP)

DIP 4

INVERSION OF THE DIRECTION

Invert direction and the limitswitch
Invert direction and the limitswitch

DIP 5

SETTING SEFETY CONTACT IN OPENING

In opening the control board stop and invert for 2sec the
gate direction
In opening the control board stop the gate direction

DIP 6

FLASHING FUNCTION

Intermittent light
Steady light

DIP 7

SLOW DOWN

Activate
Not activate

DIP 8

ENCODER

Encoder actived
Encoder not actived

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

FLASHING OPERATION WITH DIP6 ON

IN OPENING:

Flash slow

IN CLOSING:

Flash fast

IN PAUSE:

Steady light

PHOTOCELL ENGAGED:

Turn off

ENCODER OPERATION

Actived by

DIP8 ON

CHANGE OF SENSITIVITY AND TORQUE
More torque =

 less sensitivity

Less torque =

 more sensitivity

The parameters are set by

 the trimmer T1 and T2.

ON-

OFF-

ON-

OFF-

ON-

OFF-

Содержание EURO230M1

Страница 1: ... vigentes en el pais donde se lleva a cabo la installacion WARNING Before installing thoroughly read this manual that is an integral part of this Kit VDS declines any responsabilità in the event curret stadards in the country of installation are not comlplied with ATTENTION il vous plaît attentivement ce manuell installation VDS décline toute responsabilitécas de non conformité à cesèglements Appa...

Страница 2: ... l apertura e la visualizzazione della centrale Inserire ponticello ON OFF COM N C N C N C N O N O N C COM N C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COM Start Stop 2 1 7 6 Esempio cablaggio Selettore CONTATTO NA CONTATTO NC 1 2 3 4 ON PROG RADIO PED START ANT STOP LSC 24Vac M LSO STOP LSC LSO P RADIO FUSE PH2 PROG TIME POWER SLOW POWER 5 6 7 8 ON ENCODER PHO PHOTOC FLASH LAMP 230V 21 ...

Страница 3: ...glie di avere la CHIUSURA AUTOMATICA OPZIONE 2 IN ON il tempo di chiusura verrà calcolato dal momento in cui l automatismo sarà arrivato ad impegnare il finecorsa di apertura attendere il tempo di pausa desiderato dare un TERZO IMPULSO l automatismo inizierà la fase di chiusura dare quindi un QUARTO IMPULSO nel punto i cui si desidera iniziare il rallentamento in chiusura L arresto avverrà tramite...

Страница 4: ... fuerza es major torneado en sentido horario CONEXIONES L1 Led ESTADO Encendido cuando la alimentación de 230 V está conectada al cuadro L2 Led RADIO Encendido cuando pulsamos el botón de programación de los emisores P1 L3 Led PROG TIEMPO Parpadea cuando pulsamos el botón de programación del recorrido de motor P2 L4 Led START Se enciende cada vez que pulsamos el emisor ó recibe una pulsación exter...

Страница 5: ... completará la marcha y se parerà en el final de la carrera si elige una automatización sin final de carrera se debe dar un nuevo impulso para fijar el punto de la carrera de parada Si usted decide tener el CIERRE AUTOMÁTICO DIP2 ON el tiempo de cierre se calcula desde el momento que el final de carrera en abertura es ocupado esperar el tiempo de pausa deseado y pulsar el mandos para iniciar el ci...

Страница 6: ...F COM N C N C N C N O N O N C COM N C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COM Start Stop 2 1 7 6 Example wiring selector CONTACT NO CONTACT NC 1 2 3 4 ON PROG RADIO PED START ANT STOP LSC 24Vac M LSO STOP LSC LSO P RADIO FUSE PH2 PROG TIME POWER SLOW POWER 5 6 7 8 ON ENCODER PHO PHOTOC FLASH LAMP 230V 21 22 T1 T2 J1 J2 P2 P1 L1 L2 L3 L4 L5 L6 L7 L8 NC COM TX RX OFF JUMPER ON OFF JUM...

Страница 7: ...op at close limitswitch if you chose an automatism without limitswitches must give a further impulse to fix the stopping point of the stroke If you choose to have the AUTOMATIC CLOSING OPTION 2 IN ON the closing time will be calculated from the moment when the operator arrives to open limitswitch until you give the THIRD PULSE the automatism will start closure Where do you want start slowing down ...

Страница 8: ...sibilitéfonctionnement normal TRIMMER T2 Le Trimmer Power Slow règle le couple etsensibilitéla phaseralentissement Leaugmentele trimmerle sens horaire OFF JUMPER ON OFF JUMPER ON c O F F J U M P E R O N O F F J U M P E R O N s Lourde porte Porte légère L1 Led STATUS Allumé quand l unité de commande est sous tension L2 Led RADIO Allumé quand vous accédez à la mémoire radio L3 Led PROG TEMPS Allumé ...

Страница 9: ...alentissement 7 Le vantail arrêtemanœuvre à la fin de course Si vous utilisez un automatisme sans FC donnez une impulsion pour arrêter la manœuvre 8 Quand la led 3éteinte vousterminéprogrammation PROGRAMMATION SANS RALENTISSEMENT OPTION 7 OFF Réglez l option 7 sur OFF exclusionralentissement Suivezprocédure décrite précédemment programmation avec ralentissement sans transmettredeuxième impulsion p...

Страница 10: ...nel qualifié capable d évaluer les risques sont conformer à la norme UNI EN 12453 EN 12445 UNI EN I dati e le immagini sono puramente indicativi VDS si riserva il diritto di modificare in qualsiasi momento le caratteristiche dei prodotti descritti a suo insindacabile giudizio senza alcun preavviso Los datos y las imágenes son orientativos VDS se reserva el derecho de modificar en cualquier momento...

Отзывы: