Care and Service
68
VideoJet 400
When the transmission is completed, the message
transfer
complete
will be displayed and the green LED flashes. The new
firmware will now be unpacked and the flash EPROM will be repro-
grammed.
When the green LED stops flashing, programming is complete. An
automatic reset of the device is carried out and the FTP connection
is deactivated.
)
Press the keys [Ctrl] + [Break] simultaneously to terminate the FTP
session.
Checking the network
The connection between two IP addresses can be checked using
the command
ping
. You can thus check whether the
VideoJet
in the network is active.
)
Open the DOS input window
)
Enter the command
ping
followed by the IP address of the
VideoJet
.
When the
VideoJet
is found, you receive in response:
Reply
from ...
, followed by the number of bytes transmitted and the
transmission time in ms. Otherwise the
VideoJet
cannot be
addressed via the network. This can have the following causes:
z
The
VideoJet
is not correctly connected to the network. In this
case, check the connecting leads.
z
The
VideoJet
is not correctly integrated into the network.
Check the IP address, the subnet mask and the gateway IP.
Attention!
On no account interrupt the installation of the firmware. An interrup-
tion will result in damage to the flash EPROM. This can result in the
device being no longer addressable and having to be replaced.