21
VideoJet 400
Installation
4
Thanks to its compact design, the
VideoJet 400
as desktop
device requires a minimum of space.
Please observe the following installation conditions:
z
Do not install the
VideoJet
in the immediate vicinity of radia-
tors or other sources of heat. Avoid installing the
VideoJet
where it is exposed to direct sunlight.
z
Ensure sufficient space for laying the cables.
z
Ensure adequate ventilation of the
VideoJet
. In particular,
observe the heat burden when installing several devices in the
same control cabinet.
z
For all cable connections, use only the supplied or suitable
cables which also prevent any electrical interference, where
necessary.
z
Lay and install all cables in such a way that they cannot be
damaged and ensure sufficient strain relief.
Attention!
The server is designed for operation indoors. Choose a site for
installation which ensures that the server is exposed to neither
extreme temperatures nor extreme moisture or humidity. The
ambient temperature must lie b5 and +40 °C, the relative
humidity must not exceed 80%.
During operation, the server generates a great deal of heat. There-
fore ensure sufficient ventilation and an adequate distance to heat-
sensitive equipment or objects.