29
E
N
G
•
Boiler pressure
- screen where you can set the boiler pressure.
•
Enable/disable pressure profiles
- screen in which “Enable pressure profiles” will be
displayed in the case of disabled profiles and vice versa.
•
Pressure profiles
- The “Pressure profiles” function allows you to program up to ten
different coffee dispensing profiles.
In practice, the pump operates at maximum pressure and through the software it is possible
to set the pressure and the duration time in seven different segments within a profile; for
example in the first segment you can set a pressure of 5 bar for 6 seconds, in the second
segment a pressure of 7 bar for 4 seconds, etc. up to the seventh segment.
Select profile
Select the desired profile by pressing the arrows (
) then press (
) on the next two
screens to apply it.
VBM N. 1
VBM N. 3
VBM N. 2
Pressure's profiles
apply
rename
modify
09
bar
VBM n. 1
Profile successfully applied