         8

maintenance

Remove the height adjuster knob from the top of the
floor head cover. Remove the floor head cover, lifting
from the rear of the machine (Fig.7/3).

Lift the right side of the brushbar and lift the left hand
side and remove the brushbar from the floor head
(Fig.7/4).

Remove the worn or broken belt from the motor drive
shaft.

Carefully remove any belt residue that may exist in the
belt area before replacing with a new belt.

Loop the new belt first over the motor drive shaft and
then over the agitator pulley.

Insert the right side of the brushbar in first by placing the
end cap down in the slot and then so the same with the
left side. Press firmly to make sure that each end is
completely inserted.

Check to make sure that the belt is centred on the
agitator pulley and that the brushbar turns.

Replace the floor head cover then reattach the carpet
height adjuster knob. Secure parts by screwing in one (1)
screw underneath the small wheel flap and the five (5)
screws on the underside of the vacuum cleaner.

8. Clearing Blockages

WARNING : 

To reduce the risk of electric shock, the

power cord must be disconnected before

performing maintenance/ troubleshooting checks.
Turn the vacuum cleaner off and unplug from the
electrical outlet.

Hose Blockages

The flexible hose may be disconnected from the vacuum
cleaner. Carefully remove any blockages found and
reconnect hose securely.

Accessory Blockages

Remove accessory from hose/extension wand. Carefully
remove the blockage and return to the cleaner.

Clearing debris from the TurboTool (some models
only)

1. Turn the TurboTool over and slide off the O-ring
(Fig.8/1).

2. Pivot lowering housing and remove clog (Fig.8/2).

3. To re-assemble, be sure that the tabs are engaged.
Pivot the lower housing closed. Slip the O-ring into the
groove at the neck of the TurboTool to complete
reassembly (Fig.8/3).

vax.co.uk

Fig.7/3

Fig.7/4

!

Fig.8/1

Fig.8/2

O-ring

U89 U90 & U91-P2 Power 2 Series User Guide V2.0:U90-P2 User Guide  13/08/2010  11:44  Page 8

Содержание U89-P2 Series

Страница 1: ...en left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this clea...

Страница 2: ...s 22 TurboTool Some models only 1 2 14 15 16 10 5 12 13 22 22 17 6 9 3 4 7 8 20 21 WARNING This cleaner has a constantly rotating brushbar which when left in contact with lino parquet and other hard f...

Страница 3: ...hot coals cigarette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liqu...

Страница 4: ...the top in place there will be an audible click when it is secure Fig 3 3 Assembly of the Hose Align the tabs on the lower hose inspection tube with the slots on the hose Push and turn the hose clock...

Страница 5: ...uum is comfortable to push The brushbar must reach the carpet for effective cleaning Fig 4 3 IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and tools the hei...

Страница 6: ...move the dirt container press the dirt container release button and lift away from the vacuum cleaner Fig 6 1 Cleaning the HEPA Filter Remove the dirt container lid by grasping the dirt container and...

Страница 7: ...is fully dry before putting back on the vacuum cleaner Do not wash in dishwasher 7 Maintenance Cleaning and Changing the Belt TOOLS REQUIRED Crosshead screwdriver WARNING To reduce the risk of electr...

Страница 8: ...e parts by screwing in one 1 screw underneath the small wheel flap and the five 5 screws on the underside of the vacuum cleaner 8 Clearing Blockages WARNING To reduce the risk of electric shock the po...

Страница 9: ...view dirt container replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Clogged filters Solution Remove clean and replace filters PROBLEM Accessories won t pick up Cau...

Страница 10: ...uk 11 Consumables To purchase spares and accessories please visit vax co uk Filter kit 1 1 126184 00 Belt kit 1 1 130669 00 12 Technical Specification Voltage 220 240V 50Hz Wattage 1800W 2000W depend...

Страница 11: ...11 This page has been left intentionally blank Vax Careline UK 0844 412 8455 ROI 1 800 928 308 U89 U90 U91 P2 Power 2 Series User Guide V2 0 U90 P2 User Guide 13 08 2010 11 44 Page 11...

Страница 12: ...Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local A...

Отзывы: