13. Frequently asked questions

Before installing

What size building can one fresh-r

®

 ventilate?

Up to 100 m

2

, but this depends on the size, 

lay-out, number of people and the regulations, 
ask your supplier for details.

Where should I position the fresh-r

®

 in the 

building?

Centrally and ideally at least 80cm from the 
floor level, but not too high because you need 
to be able to see the controls easily. Make sure 
air distributes evenly between different rooms. 
Ask your supplier for details

Will the unit work in a bathroom?

We do not recommend to use a fresh-r

®

 in the 

bathroom, we recommend to use an 
alternatieve solution, ask your supplier for 
details.

Will the unit work in the toilet?

Yes, contact your supplier for details.

What should I do when the kitchen hood is on?

Make sure there is enough airflow towards the 
kitchen hood, we recommend a kitchen hood 
with a maximum capacity of 300 m3/hr, 
contact your supplier for details.

Will the air be distributed in the room?

Yes, CO² travels easily but proper air 

circulation is needed between the rooms, 
contact your supplier for details.

Can the fresh-r

®

 be installed horizontally?

No, the condensate will not be guided 
correctly, contact your supplier for details.

Can the fresh-r

®

 be mounted upside down?

No, the condensate will not be guided 
correctly, contact your supplier for details.

Where does the air enter the room?

From the bottom of the door.

Where is the air extracted from the room?

From the top of the door.

Why should we not mount the unit close to the 
ground?

Because it is more efficient to take warm air 
from the top of the room and it give better air 
circulation when bringing in fresh-r

®

 air in the 

middle of the room.

While installing

What distance is needed between the 2 duct holes?

897 +/- 2 mm from centre to centre.

Why does the lower duct need to be positioned at a 
2 degree angle?

It needs to drain condensate to the outside.

Why does the lip of the lower duct pipe need to 
have overlap with the grilles?

In order to guide the water from the wall 
surface, so the condensate drops on the ground 
and not cause green streaks on the outer wall.

Why does the lower duct pipe need a water tight 
connection with the Unibody?

When heat is exchanged condensation can 
sometimes occur, this condensate is guided 
through the Unibody through the lower duct 
pipe to the outside.

Содержание fresh-r everywhere On-The-Wall

Страница 1: ...IMPORTANT Read this manual carefully before installing the fresh r Keep this manual for future use On The Wall Installation manual...

Страница 2: ...ity supply and must be connected by a qualified electrician Other information relating to the target group can be found in chapter 2 The information in this manual is important for the correct and saf...

Страница 3: ...Specifications 23 11 Who can I contact for questions spareparts or more information 23 12 Warranty 23 13 Frequently asked questions 24 14 Declaration of conformity 26 15 Appendix 27 15 1 Technical dra...

Страница 4: ...may only be installed on a wall 2 Target group The manual describes how to install the fresh r The installation must be done by contractors who are familiar with local building regulations Connecting...

Страница 5: ...ply in the distribution box before connecting the fresh r electrically The person responsible for installing the fresh r should be familiar with the local building regulations 5 Main components A B C...

Страница 6: ...vel or another tool to check for a prefect vertical position Deburring or grinding tool such as a file EPP Glue and expanding foam 7 How to install the fresh r DANGER The person responsible for instal...

Страница 7: ...supplied See fig 3 and fig 4 Draw the holes To draw the holes do the following 1 Place the template against the outer wall make sure it s vertically leveled 2 Tape the template on the wall Use removab...

Страница 8: ...wall is well prepared 2 Remove dust and other materials from the holes 3 Get a duct pipe this is the blue PVC pipe with EPP cover this is a foam tube and try if it fits the holes The four corner holes...

Страница 9: ...9 fig 6 Check the dimensions of the corner holes before drilling 243 mm 105 mm 111 mm 1055 mm...

Страница 10: ...input fresh air to the total width of the wall D1 15 mm Tip Use a wide tape or two paper sheets taped together to mark the duct pipes and get a perpendicular cut 3 Cut the lower duct pipe output stale...

Страница 11: ...oist indoor air may reach the cold ducts 1 Put PVC glue on the white ring which is located in the inside of the stale air output socket see fig 9 Do not put PVC glue on the freh air input tube fig 9 P...

Страница 12: ...3 Put EPP glue on the Unibody around the PVC duct pipes fig 11 Put EPP glue on the Unibody around the PVC duct pipes 4 Place the EPP covers on the duct pipes fig 12 Place the EPP covers Epp glue Epp g...

Страница 13: ...upper duct pipe to the Unibody needs to be airtight because air leaks can create unwanted condensation fig 13 Put EPP glue around the edges of the covers 6 Cut the Epp covers They need to cover the wh...

Страница 14: ...Make sure the expanding foam insulate the whole edge of the EPP covers in order to prevent air leaking regarding the inner wall fig 17 Put expanding foam around the edge of both EPP covers 3 Place the...

Страница 15: ...by two persons First read step 5 6 and 7 so you are well prepared Then perform the actions CAUTION Be carefull with the door Giving too much pressure can damage the door or it s hinges fig 19 Be care...

Страница 16: ...on the wall 6 The second person Mount the 6 x 120 screws in each corner of the Unibody 4 Use a screw driver CAUTION The ducts and the holes must have an air tight seal To establish this it s critical...

Страница 17: ...onality DANGER Connecting the fresh r to the mains electricity supply must be done by a qualified electrician Risk for electric shocks or electrocution Turn off the mains electricity supply in the dis...

Страница 18: ...ing If not Check the main electricity supply If the product still does not work turn the unit OFF and contact your supplier 7 Place the grilles assembly find the content in Bag B Do the following 1 Mo...

Страница 19: ...19 fig 25 Lip should overlap with the edge of the grilles...

Страница 20: ...ease fan speed for approximately 5 seconds until you hear a beep Then wait 10 seconds 3 Press the lower button decrease fan speed for approximately 5 seconds until you hear a beep the WiFi chip is now...

Страница 21: ...u can normally find it on a sticker on the router itself 12 Enter your WiFi passphrase wireless key also called password in the Passphrase box Tip Check the Show Passphrase to visually check that you...

Страница 22: ...VC Glue Page 11 step 1 Are the duct pipes sealed against the the EPP back cover Page 12 step 3 4 Are the duct covers sealed against the the EPP back cover Page 13 step 5 Are the duct pipes sealed agai...

Страница 23: ...kg Dimensions 1143 mm 300 mm 160 mm Capacity Automatic regulation upto 120m3 hr Continues heat recovery at sub zero temperatures Yes with automatic defrost mode Full automatic operation Self regulatin...

Страница 24: ...supplier for details Can the fresh r be installed horizontally No the condensate will not be guided correctly contact your supplier for details Can the fresh r be mounted upside down No the condensate...

Страница 25: ...erate the unit On the control panel A for automatic You can increase or decrease the fan speed manually using the fan buttons Refer to the user manual Increase or lower fans speed via the fan buttons...

Страница 26: ...The Netherlands declare under our sole responsibility that the following product E quipment Air handling unit with heat recovery Brand name Vaventis Model type Fresh r is in conformity with the follo...

Страница 27: ...27 15 Appendix 15 1 Technical drawings 15 1 1 fresh r Dimensions are in mm Dimensions in brackets are in inches...

Страница 28: ...28 15 1 2 fresh r with rectangular duct on top Dimensions are in mm Dimensions in brackets are in inches...

Страница 29: ...29 15 1 3 Outer wall template Dimensions are in mm Dimensions in brackets are in inches...

Страница 30: ...everywhere to your in house extraction duct fig 26 Example of an extract duct connected to the top of the fresh r everywhere To make this connection three extract ducts can be used 100 3 937 204 8 032...

Страница 31: ...ons are in mm Dimensions in brackets are in inches 100 3 937 204 8 032 60 2 362 15 2 2 Rectangular right angle duct dimensions 100 3 937 204 8 032 60 2 362 205 8 071 2 places 61 2 402 2 places 50 1 96...

Страница 32: ...32 15 2 3 Rectangular ro round duct dimensions Dimensions are in mm Dimensions in brackets are in inches 120 4 724 220 8 661 126 4 961...

Страница 33: ...33...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...www vaventis com 2015 by Vaventis B V All right reserved...

Отзывы: