Installation, Operating & Maintenance Instructions
Series 612 DN 63-250 (I.D. 2.5“ - 10”), RS485
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
289857EA
2011-07-13
10/76
1. Install valve [1] into the vacuum system.
Caution: Do not tighten the flange screws stronger than indicated under «Tightening torque».
Caution: Do not admit higher forces to the valve than indicated under «Admissible forces».
Note: Make sure that enough space is kept free to do preventive maintenance work. The required space is indicated
on the dimensional drawing.
Note: Control unit of valves with ISO-KF flanges (612 . . – K . . . ) needs support when mounted on horizontal piping
and control unit does not hang.
2. Install the ground connection cable at controller. Refer to «Electrical connection»
3. Install sensor(s) [2] according to the recommendations of the sensor manufacturer and directives given under
«Requirements to sensor connection».
4. Connect sensor cable [3] to sensor(s) and then to valve (connector: SENSOR).
Refer to chapter «Electrical connection» for correct wiring.
Note: Input for second sensor is available on 612 . . - . . . E versions.
5. Connect valve (connector: INTERFACE) to remote control unit [4]. Refer to «RS485 schematics» for correct wiring.
6. Connect power supply [5] to valve (connector: POWER). Refer to chapter «Electrical connection» for correct wiring.
Note: To provide power to the valve motor pins 4 and 8 must be bridged, otherwise motor interlock is active and the
valve enters the safety mode and is not operative. Refer also to «Safety mode».
7. This valve may optionally be equipped with a heating device. Connect VAT heating device according to manual of
respective heating device.
8. Perform «Setup procedure» to prepare valve for operation.
Note: Without performing the setup procedure the valve will not be able to do pressure control.