![VAT 615 AG Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/vat/615-ag-series/615-ag-series_installation-operating-and-maintenance-instructions_855895038.webp)
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
290227EA
2011-06-24
38/79
3.11.2 Schematics
This interface allows for remote operation by means of a command set based on the RS232 protocol.
In addition there are 2 digital inputs and 2 digital outputs. Digital inputs may be operated either by switches or by voltage
sources.
Note: Optional analog outputs are available on 615 . . - . . . V - . . . . and 615 . . - . . . W - . . . . versions only.
Active digital inputs have higher priority than RS232 commands.
a) Configuration with switches for digital inputs:
Note: Do not connect other pins than indicated in the schematics above!
Connector: Use only screws with 4-40UNC thread for fastening the DB-25 connector!