![VAT 48 Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/vat/48-series/48-series_installation-operating-and-maintenance-instructions_3953584023.webp)
Series 48
DISMOUNTING AND STORAGE
288914ED
Edition 2013-05-24
23/27
8.1
Dismounting
NOTICE
Valve in open position
Valve mechanism may get damaged if valve is in open position.
Close valve before dismounting the valve from the system.
1. Close valve.
2. Disconnect electrical power supply.
3. Disconnect compressed air supply.
4. Dismount valve according chapter «4 Installation», however in reverse order.
Observe safety instruction of chapter «4 Installation».
8.2
Storage
NOTICE
Wrong storage
Inappropriate temperatures and humidity may cause damage to the product.
Valve must be stored at:
– relative humidity between 10% and 70%
– temperature b10 °C and +50 °C
– non-condensing environment
NOTICE
Inappropriate packaging
Product may get damaged if inappropriate packaging material is used.
Always use the original packaging material and handle product with care.
1. Clean / decontaminate valve.
2. Mount protective covers on flanges; see chapter «4.2.1 Preparation for installation».
3. Pack valve appropriately, by using the original packaging material.