![VAT 48 Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/vat/48-series/48-series_installation-operating-and-maintenance-instructions_3953584019.webp)
Series 48
OPERATION
288914ED
Edition 2013-05-24
19/27
5.6
Trouble shooting
Failure
Check
Action
See
Valve
mechanism does
not move
Air pressure
Connect
compressed air
«4.3 Compressed air
connection»
Electrical power
Connect electrical
power
Operating
pressure
Adjust operating
pressure
«4.3 Compressed air
connection»
Position of
slotted screw
Turn slotted screw to
the correct position
«5.5.1 Manual emergency
operation»
Leak at gate
Condition of gate
seal
Please contact VAT
Condition of
valve gate
Please contact VAT
Operating
pressure
Adjust operating
pressure
«4.3 Compressed air
connection»
Leak at body
Condition of
bonnet seal and
sealing surface
Please contact VAT
Condition of
bellows
Please contact VAT
Whistling sound
during opening
or closing
–
No action required
when valve is actu-
ated at atmosphere
–
–
No action required
when valve is actu-
ated in vacuum as
long as the sound is
not excessive
–
Table 5-4
If you need any further information, please contact one of our service centers. You will find
the addresses on our website www.vatvalve.com.