3.5
General specifications
3.5.1
Motor code
MAC-HS series motors are coded as follows:
MAC
HS
200
M
H41
Motor type
Series
Size
Length
Winding
MAC
Asynchronous Motor
for Inverter Duty
IP23 – IC06
HS4
4 pole / High-speed
100
132
160
200
250
Shaft height
(mm)
S
M
L
P
X
Defines the rated
motor speed
MAC
Asynchronous Motor
for Inverter Duty
IP23 – IC06
HS2
2 pole / High-speed
225
250
Shaft height
(mm)
L
Defines the rated
motor speed
Table 13: MAC-HS motor codes
3.5.2
Ambient conditions
In their standard version, MAC HS motors are not suitable for working in saline or corrosive atmospheres or for installation
outdoors.
3.5.3
Duty
The rated power assigned for continuous service (S1 duty type) assumes an ambient temperature between -20º and +40ºC and
altitudes of up to 1000 m.
If the working conditions are different from those above, a derating factor (K1) must be applied to the rated torque and power
(See table below):
Altitude
Temperature
30ºC
40ºC
50ºC
55ºC
1000 [m]
1
1
0.92
0.86
2000 [m]
1
0.93
0.85
0.77
3000 [m]
0.93
0.85
0.76
0.69
4000 [m]
0.86
0.78
0.67
0.6
Table 14: Declassing factors