Electrical connection

Wiring diagram and control panel

Installation must be in accordance with the High Current Regulations 
[Starkströmsföreskrifterna], under the supervision of an authorised elec

-

trical installer.

Electrical connection

The boiler is connected directly to the mains (no plug) using a 

rubber cable, via an all-pole circuit breaker with a contact gap 
of at least 3 mm.
The electrical connections are at the rear of the boiler, in the 
form of three quick connectors:

15. Mains connection, 230V~. Cable with quick connectors supplied.
16. Fan.
17. Circulation pump, for charging the accumulator system.

Supply

Fan

Circulation pump

YELLOW/GREEN

YELLOW/GREEN
BLUE

BLACK

BLACK

BLUE

15

16

17

15. Supply connection, 

3-pole connector. 
  a. cable part, socket. 
  b. chassis part, plug.

16. Fan connection, 

5-pole connector. 
  a. cable part, plug. 
  b. chassis part, socket.

17. Connection for accumulator system 

charging pump, 
3-pole connector. 
  a. cable part, plug. 
  b. chassis part, socket.

18. Terminal block for internal earth 

connections.

19. Start capacitor for fan motor.
20. Main switch.
21  Thermostat for fan and charging 

pump.

22. Fan start when the boiler is cold.
23. Relay.

25

15a

16a

17a

18

19

20

21

22

23

24

26

15b

17b

16b

20

22

21

25

26

27

28

24. Time relay, delayed cutoff.
25. Overheating protection.
26. Indicator showing triggered over-

heating protection.

27. Thermometer, displays the boiler 

temperature.

28. Pressure gauge showing the water 

pressure in the heating system.

Function

Start with the boiler cold.
Set the main switch, 20, to the ON position – the green area 
must be visible.

Set the thermostat, “FAN STOP”, 21, to 120°C. The thermostat 

detects the flue gas temperature.
Press “FAN START”, 22, the time relay, 24, is activated and the 
fan starts.

When the time set for the time relay, 30 minutes, is reached, the 

contact changes, which means that the fan and the charging 
pump for the accumulator system are controlled by the thermo-
stat, 21.

When the firewood is burnt out and the flue gas temperature 

falls below the value set for the thermostat, 21, the fan and 
charging pump stop running.

If the boiler temperature exceeds 110°C, the overheating pro

-

tection is triggered. The fan stops running and the charging 
pump continues to operate.
If the overheating protection, 25, is triggered, the “ALARM” indi-
cator , 26, is lit. The relay, 23, prevents the time relay activating 
when the overheating protection is triggered.
To reset the overheating protection, press “RESET”, 25, on the 
boiler control panel. It is not possible to reset the system until 

the boiler temperature has dropped below 95°C.

Содержание Vedolux 37

Страница 1: ...ion operation and maintenance Vedolux 37 08 03 ver 3 RVR 0811 From serial no VB THL product no Arkelstorpsv gen 88 291 94 KRISTIANSTAD Tel 044 22 63 20 Fax 044 22 63 58 info varmebaronen se ww varmeba...

Страница 2: ...eaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are round which means there are...

Страница 3: ...nnection fan 17 Electrical connection circulation pump for accumulator charging 18 Flue pipe straight up with socket R25 for support pipe accessory 19 Base frame accessory The manufacturer reserves th...

Страница 4: ...urface area The schematic diagram below shows the Vedolux 37 with the Aqualux and Aqualux UB accumulator tanks plus Accumulator Control 3 For more details refer to the documentation supplied with the...

Страница 5: ...draining For filling the shunt valve must be fully open Turbulators The five turbulators are installed in the flue gas pipes as shown in the diagram The purpose of the turbulators is to introduce turb...

Страница 6: ...9 20 21 22 23 24 26 15b 17b 16b 20 22 21 25 26 27 28 24 Time relay delayed cutoff 25 Overheating protection 26 Indicator showing triggered over heating protection 27 Thermometer displays the boiler te...

Страница 7: ...fter the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another few weeks of drying the wood has 2...

Страница 8: ...d hatch followed by the bypass damper If the flue gas temperature increases you know that the firewood has ignited When the firewood has burnt and the flue gas temperature has fallen to be low 120 C t...

Страница 9: ...less of the heat escapes with the flue gases One way of telling whether it is time for cleaning is to check the flue gas thermostat It is a good idea to clean the boiler if the flue gas temperature is...

Страница 10: ...on the height difference between the highest and lowest points in the system the static head Note that the pressure in the system varies with the boiler tem perature do not add water unnecessarily The...

Страница 11: ...increased quickly before charging begins Add a control system Ceramic not correctly positioned If the boiler is new check that the ceramic has not moved during transport There is no need to remove the...

Страница 12: ...Draught hatch V 37 1 37 00 60 Handle knob 25 mm 2 28 38 00 01 Manometer 0 4 bar 1 27 38 00 03 Thermometer 0 120 C 1 38 00 30 Flue gas thermometer 50 500 C 1 44 00 02 Pipe cleaner 89 mm 2 44 00 05 Pip...

Отзывы: