2

2008-03

Vedolux 37

Contents

Function ................................................................. 2
Technical data ....................................................... 3
Installation ............................................................ 4

General
Chimney
Flue pipe
Flue gas thermometer
Connection to accumulator system
Function of accumulator control
Shunt valve
Expansion system
Cooling coil – temperature limiter
Radiator pump
Filling the heating system
Turbulators
Bracket for cleaning tool
Draught hatch
Pellet burner
Oil burner

Electrical connection ............................................ 6

General
Electrical connection

Wiring diagram and control panel ........................ 6

Function

Checks ................................................................... 7

General
Checks

Firewood ................................................................ 7

Firewood as a fuel
Firewood
Heat content
First burning cycle

Function

Vedolux 37

•  is a firewood boiler with a suction fan, designed for heating 

houses and smaller properties.

•  is environmentally-approved for firewood burning with an ac

-

cumulator tank.

• is designed for half metre firewood.
• is designed to be connected to an external water heater.
•  is primarily designed to be fired by firewood, but can also eas

-

ily be modified for use with an oil or pellet burner.

•  has an output of 37 kW when burning firewood and 50 kW 

when burning oil/pellets.

Ceramic combustion chamber

The combustion chamber is designed for reverse combustion. 
The depth of the combustion chamber is 550 mm. A bypass 

damper prevents smoke entering the room when firewood is 

added.

Flue cleaning

All flue ducts in the boiler are cleaned from the same hatch at 
the front of the boiler. The hatch is hinged and is opened with a 
single operation. The flue ducts are round, which means there 
are no awkward corners when flue cleaning.

Chimney

The Vedolux 37 has a suction fan minimising the chimney re

-

quirements of the boiler.

Accumulator tank

To optimise combustion and efficiency, and to meet environ

-

mental requirements relating to firewood burning, the boiler 

must be connected to an accumulator tank. The accumulator 
tank is dimensioned according to the requirements of the build-
ing.

Delivery

The product is delivered with the following components:

 flue pipe.

 flue cleaning tool with bracket.

 flue gas thermometer.

 drain valve.

 gas lighter.

Accessories

 base frame to make firewood burning more convenient.

 Accumulator Control 3.

  accessory for oil/pellet firing (cover plate with draught hatch for 

fan).

Firewood as a fuel ................................................. 8

Startup
First burning cycle
Lighting – start

Lighting a fire with the gas lighter

Adding wood
Bypass damper
Controlling combustion
Inner ash hatch

Flue cleaning ......................................................... 9

General
Cleaning the boiler
Chimney sweeping
Cleaning the fan

Operation and maintenance ............................... 10

Ceramic – combustion tunnel
Safety valves
Venting

Water pressure in the system

Unvented expansion system
Overheating protection
If there is a risk of freezing
Draining the boiler
Boiler cleaning
Pellet burner
Oil burner

Problems burning firewood ................................. 11

Component specification .................................... 12

Содержание Vedolux 37

Страница 1: ...ion operation and maintenance Vedolux 37 08 03 ver 3 RVR 0811 From serial no VB THL product no Arkelstorpsv gen 88 291 94 KRISTIANSTAD Tel 044 22 63 20 Fax 044 22 63 58 info varmebaronen se ww varmeba...

Страница 2: ...eaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are round which means there are...

Страница 3: ...nnection fan 17 Electrical connection circulation pump for accumulator charging 18 Flue pipe straight up with socket R25 for support pipe accessory 19 Base frame accessory The manufacturer reserves th...

Страница 4: ...urface area The schematic diagram below shows the Vedolux 37 with the Aqualux and Aqualux UB accumulator tanks plus Accumulator Control 3 For more details refer to the documentation supplied with the...

Страница 5: ...draining For filling the shunt valve must be fully open Turbulators The five turbulators are installed in the flue gas pipes as shown in the diagram The purpose of the turbulators is to introduce turb...

Страница 6: ...9 20 21 22 23 24 26 15b 17b 16b 20 22 21 25 26 27 28 24 Time relay delayed cutoff 25 Overheating protection 26 Indicator showing triggered over heating protection 27 Thermometer displays the boiler te...

Страница 7: ...fter the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another few weeks of drying the wood has 2...

Страница 8: ...d hatch followed by the bypass damper If the flue gas temperature increases you know that the firewood has ignited When the firewood has burnt and the flue gas temperature has fallen to be low 120 C t...

Страница 9: ...less of the heat escapes with the flue gases One way of telling whether it is time for cleaning is to check the flue gas thermostat It is a good idea to clean the boiler if the flue gas temperature is...

Страница 10: ...on the height difference between the highest and lowest points in the system the static head Note that the pressure in the system varies with the boiler tem perature do not add water unnecessarily The...

Страница 11: ...increased quickly before charging begins Add a control system Ceramic not correctly positioned If the boiler is new check that the ceramic has not moved during transport There is no need to remove the...

Страница 12: ...Draught hatch V 37 1 37 00 60 Handle knob 25 mm 2 28 38 00 01 Manometer 0 4 bar 1 27 38 00 03 Thermometer 0 120 C 1 38 00 30 Flue gas thermometer 50 500 C 1 44 00 02 Pipe cleaner 89 mm 2 44 00 05 Pip...

Отзывы: