Vedolux 37
Contents
Function ................................................................. 2
Technical data ....................................................... 3
Installation ............................................................ 4
General
Chimney
Flue pipe
Flue gas thermometer
Connection to accumulator system
Function of accumulator control
Shunt valve
Expansion system
Cooling coil – temperature limiter
Radiator pump
Filling the heating system
Turbulators
Bracket for cleaning tool
Draught hatch
Pellet burner
Oil burner
Electrical connection ............................................ 6
General
Electrical connection
Wiring diagram and control panel ........................ 6
Function
Checks ................................................................... 7
General
Checks
Firewood ................................................................ 7
Firewood as a fuel
Firewood
Heat content
First burning cycle
Function
Vedolux 37
• is a firewood boiler with a suction fan, designed for heating
houses and smaller properties.
• is environmentally-approved for firewood burning with an ac
-
cumulator tank.
• is designed for half metre firewood.
• is designed to be connected to an external water heater.
• is primarily designed to be fired by firewood, but can also eas
-
ily be modified for use with an oil or pellet burner.
• has an output of 37 kW when burning firewood and 50 kW
when burning oil/pellets.
Ceramic combustion chamber
The combustion chamber is designed for reverse combustion.
The depth of the combustion chamber is 550 mm. A bypass
damper prevents smoke entering the room when firewood is
added.
Flue cleaning
All flue ducts in the boiler are cleaned from the same hatch at
the front of the boiler. The hatch is hinged and is opened with a
single operation. The flue ducts are round, which means there
are no awkward corners when flue cleaning.
Chimney
The Vedolux 37 has a suction fan minimising the chimney re
-
quirements of the boiler.
Accumulator tank
To optimise combustion and efficiency, and to meet environ
-
mental requirements relating to firewood burning, the boiler
must be connected to an accumulator tank. The accumulator
tank is dimensioned according to the requirements of the build-
ing.
Delivery
The product is delivered with the following components:
•
flue pipe.
•
flue cleaning tool with bracket.
•
flue gas thermometer.
•
drain valve.
•
gas lighter.
Accessories
•
base frame to make firewood burning more convenient.
•
Accumulator Control 3.
•
accessory for oil/pellet firing (cover plate with draught hatch for
fan).
Firewood as a fuel ................................................. 8
Startup
First burning cycle
Lighting – start
Lighting a fire with the gas lighter
Adding wood
Bypass damper
Controlling combustion
Inner ash hatch
Flue cleaning ......................................................... 9
General
Cleaning the boiler
Chimney sweeping
Cleaning the fan
Operation and maintenance ............................... 10
Ceramic – combustion tunnel
Safety valves
Venting
Water pressure in the system
Unvented expansion system
Overheating protection
If there is a risk of freezing
Draining the boiler
Boiler cleaning
Pellet burner
Oil burner
Problems burning firewood ................................. 11
Component specification .................................... 12