Vedolux 37

Problems burning firewood

The most common problems that occur when burning firewood are usually the result of the boiler failing to reach a high enough temperature so 
that the boiler never really gets going. Another common problem is that the heat is not transferred to the accumulator tanks even though the 
wood is burning well in the boiler.

Poor combustion in the boiler Damp wood.

A ceramic boiler requires a high combustion temperature. To 

achieve this, the wood must be dry, moisture content 12- 30%.

Incorrect handling.

Read the instructions.

The wood is not suitable for the 

boiler.

The firewood should be 50 cm long. The thickness should allow 

three blocks to fit the width of the grate.

Shaped wood, rectangular wood. If uniform blocks of wood are stacked on each other, a sold mass 

of wood is created with limited surface area for the fire to act on. 

Arrange the wood so there are gaps between the blocks.

Fails to burn.

This happens when the wood is bent and is not suitable for the 

boiler. Use wood that is suitable for the boiler.

Inadequate air supply.

The fresh air intake of the boiler room must have at least the same 

cross sectional area as the flue duct. Check that the air valve is 

open.

Secondary/tertiary damper too 

open.

If the damper is too open, the primary and secondary air will be 

incorrectly distributed. Start with the secondary damper fully 

closed. It will never normally be necessary to open it by more than 

a few millimetres (glass).

The chimney runs downwards 

from the boiler connection.

The turbulence created takes away some of the draught. Fill the 

lower part with sand or similar material.

No accumulator control.

A ceramic boiler is at its most efficient when the ceramic is hot. 

The temperature in the boiler therefore needs to be increased 

quickly before charging begins. Add a control system.

Ceramic not correctly positioned. If the boiler is new, check that the ceramic has not moved during 

transport. There is no need to remove the ceramic, even for clean-

ing. However, if it is removed anyway, make sure it is replaced cor-

rectly. Check the seal with the combustion chamber walls.

High flue gas temperature.

Tar, soot in the pipes.

Due to incorrect combustion. Check the firewood, the draught, 

the air intake and the handling. Clean the boiler.

Bypass damper open.

Close the damper. The bypass damper must only be opened for 

adding wood.

Combustion tunnel in wrong posi-

tion.

The combustion tunnel must be inserted as illustrated on page 9.

Faulty flue gas thermometer.

The thermometer may have been damaged by cleaning or by 

long periods of updraught burning.

Tar and large quantities of soot 

in the pipes.

Incorrect combustion.

See the section about high flue gas temperature.

Wrong connections.

Check.

Heat is not transferred from the 

boiler to the accumulator.

Circulation pump too small.

The pump must have sufficient capacity to transfer the heat. 

Change to a larger pump.

Air.

If you make the connections as suggested, the system will not be 

sensitive to air problems. Vent.

Wrong connection of accumula

-

tor.

See the points above.

Boiling noises in the boiler.

Low pressure head.

Check the pressure, which should be about 1 bar. The expansion 

vessel must be dimensioned for the volume and for the tempera-

ture variations that occur.

Fan fails to start

Main switch in position O.

Set the main switches to position I.

Forgotten to connect the instant 

connector.

Connect the instant connector.

Overheating protection triggered. Reset the overheating protection.

The safety valve opens when 

the system heats up.

Expansion vessel too small.

See the section about the “Expansion system” on page 5.

Initial pressure in the expansion 

vessel too high/low.

Check the pressure in the vessel, see the section about the “Ex-

pansion system” on page 5.

Содержание Vedolux 37

Страница 1: ...ion operation and maintenance Vedolux 37 08 03 ver 3 RVR 0811 From serial no VB THL product no Arkelstorpsv gen 88 291 94 KRISTIANSTAD Tel 044 22 63 20 Fax 044 22 63 58 info varmebaronen se ww varmeba...

Страница 2: ...eaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are round which means there are...

Страница 3: ...nnection fan 17 Electrical connection circulation pump for accumulator charging 18 Flue pipe straight up with socket R25 for support pipe accessory 19 Base frame accessory The manufacturer reserves th...

Страница 4: ...urface area The schematic diagram below shows the Vedolux 37 with the Aqualux and Aqualux UB accumulator tanks plus Accumulator Control 3 For more details refer to the documentation supplied with the...

Страница 5: ...draining For filling the shunt valve must be fully open Turbulators The five turbulators are installed in the flue gas pipes as shown in the diagram The purpose of the turbulators is to introduce turb...

Страница 6: ...9 20 21 22 23 24 26 15b 17b 16b 20 22 21 25 26 27 28 24 Time relay delayed cutoff 25 Overheating protection 26 Indicator showing triggered over heating protection 27 Thermometer displays the boiler te...

Страница 7: ...fter the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another few weeks of drying the wood has 2...

Страница 8: ...d hatch followed by the bypass damper If the flue gas temperature increases you know that the firewood has ignited When the firewood has burnt and the flue gas temperature has fallen to be low 120 C t...

Страница 9: ...less of the heat escapes with the flue gases One way of telling whether it is time for cleaning is to check the flue gas thermostat It is a good idea to clean the boiler if the flue gas temperature is...

Страница 10: ...on the height difference between the highest and lowest points in the system the static head Note that the pressure in the system varies with the boiler tem perature do not add water unnecessarily The...

Страница 11: ...increased quickly before charging begins Add a control system Ceramic not correctly positioned If the boiler is new check that the ceramic has not moved during transport There is no need to remove the...

Страница 12: ...Draught hatch V 37 1 37 00 60 Handle knob 25 mm 2 28 38 00 01 Manometer 0 4 bar 1 27 38 00 03 Thermometer 0 120 C 1 38 00 30 Flue gas thermometer 50 500 C 1 44 00 02 Pipe cleaner 89 mm 2 44 00 05 Pip...

Отзывы: