Värmebaronen 400V3~: EP 450, -510, -540, -600, -700 TL / 690V3~: EP 600, -750 TL
Window two
- - î î î î î î - -
ĮTIME BLOCK ENABLED
PEC MAX. LIMIT 200
OVER TEMP FUNCTION Rel
OVER TEMP LEVEL +10°C
--------------------
- - ï ï ï ï ï ï - -
- - î î î î î î - -
ĮTIME BLOCK ENABLED
PEC MAX LIMIT 200
O-TEMP FUNCTION Rel
O-TEMP LEVEL +10°C
EXT TEMP.ADJ NO
- - ï ï ï ï ï ï - -
ĮTIME BLOCK ENABLED
Limits power connection after a power cut which has lasted
longer than three minutes. See 'Delayed power connection'
under 'Operation and maintenance', options:
Switched off: no function.
Activated: delayed power connection.
ĮPEC MAX. LIMIT 200
Limit value, 0 - 500 quality factor, for PEC function alarm.
ĮO-TEMP FUNCTION Rel
ĮO-TEMP LEVEL +10°C
Over temperature function:
Rel: over temperature, 5 - 15°C, relative to setpoint.
Abs: absolute value for over temperature , 105 - 106°C
Temperature level for the over temperature function, range:
5 - 15°C when relative to setpoint is selected.
35 - 105°C for absolute temperature.
with UTK
ĮExt. TEMP.ADJ NO
Will the function be used with closing or open contact,
alternative:
No
J2
→
O open
J2
→
C closed
Installation menu
Window three
- - î î î î î î - -
ĮSINGLE
--------------------
- MENU SELECTOR
ĮSINGLE
Information, changes with series operation, option.