15
12a
12
13
13e
13d
12b
13
Exchange
the micro switch (with bracket) for the safety guard
in the following way:
a)
Remove the rear part
(1)
, the lid of the mixer
(2)
and the operation panel
(3)
.
b)
Take off the planetary head pulley
(6D).
c)
Remove the top plate
(13A)
by first removing the four screws
(13B)
and thereafter the
screws
(13C)
.
d)
Remove the planetary head
(10).
e)
Cut the strips that holds the cables in the machine’s top, so that the cables can be moved.
f)
The plug on the cable to the switch
(13E)
is disconnected from the female connector.
g)
The bracket with the micro switc is removed by loosen the screws
(13D).
e)
Follow the instructions in reverse order.
note the torques declared for tightening
screws
12
Exchange
the switch for bowl lift
in the following way:
a)
Take off the cover plate
(8A)
on the back of the mixer.
b)
Take out the frequency converter
(8)
with fittings
(8D).
c)
The bowl detector switch
(12)
can be taken out by loosening the
two nuts
(12B)
and removing the two red wires. Location of the
jumper must not be changed.
d)
Mount the new switch on the bracket.
e)
The wires must be fitted on the switch so that the two middle
legs are empty
Screws to be
tightened with
a torque
10A - 8,8 Nm
13B - 18 Nm
13C - 9 Nm