13
C
all
uP
an
error
loG
of
the
laSt
10
dISConneCtIonS
:
The last 10 disconnections due to errors resulting in code
can be read on the mixer display:
•
Press the emergency stop
•
Press
and
to browse the log
•
The diodes on the speed indicator light up. The age of the error is indicated by the diode that illuminates:
The first diode lights up – the last (most recent) error code is displayed
The second diode lights up – the second-last error code is displayed
The third diode lights up – the third-last error code is displayed, etc.
e
rror
CodeS
dISPlayed
In
the
error
loG
:
Display
on the
mixer
Reason for error
User
Engineer
Fault correction
Frequency
transformer
display
Error description
1
Error in frequency transformer
Call the engineer
UU
DC bus undervoltage
2
Error in frequency transformer
Call the engineer
OU
DC bus overvoltage
3
Overloading of the frequency
transformer
Reduce the quan-
tity in the bowl
OI.AC
Overcurrent at drive output
4
Overloading of the frequency
transformer
Reduce the quan-
tity in the bowl
OI.br
Braking IGBT transistor overcurrent
6
1 phase of supply voltage missing
Call the engineer
ph.AC
Loss of a motor phase with brake enabled
7
??
OSP
Over speed
19
Overloading of the frequency
transformer
Reduce the quan-
tity in the bowl
it.br
Braking resistor overload I x t
20
Overloading of the motor
Reduce the quan-
tity in the bowl
it.AC
Motor overload I x t
21
Overloading of the frequency
transformer
Reduce the quan-
tity in the bowl
Oht1
IGBT overheating detected by internal sensor
22
Overloading of the frequency
transformer
Reduce the quan-
tity in the bowl
Oht2
Internal braking resistor overheating detected by
thermal sensor
24
Overloading of the motor
Reduce the quan-
tity in the bowl
th
Motor thermal sensor has tripped
26
Error in frequency transformer
Call the engineer
O.Ld1
Overload on the +24V power supply or digital
27
Error in frequency transformer
Call the engineer
CL1
Loss of the current reference on analog input
ADI1
28
Error in frequency transformer
Call the engineer
CL2
Loss of the current reference on analog input
ADI2
29
Error in frequency transformer
Call the engineer
CL3
Loss of the current reference on analog input
ADIO3
30
Connection broken between panel
and frequency transformer
Call the engineer
SCL
Loss of serial link communication
31
Error in frequency transformer
Call the engineer
EEF
EEPROM trip or transfer problem with XPress-
Key (drive and key version different)
33
Error in motor
Call the engineer
rS
Trip during measurement of the stator resistance
34
Error in frequency transformer
Call the engineer
Fbus
Disconnection of the fieldbus during operation or
error detected by the bus option
35
Connection broken from saftey cir-
cuit to frequency transformer
Call the engineer
Secd
Secure disable input trip
36
Error in voltage supply to the mixer
Call the engineer
Enc1
Loss of channel U
37
Error in voltage supply to the mixer
Call the engineer
Enc2
Loss of channel V
38
Error in voltage supply to the mixer
Call the engineer
Enc3
Loss of channel W