Page 30
MST-2B
SECONDARY FUNCTIONS
HUMIDITY SET POINT
The MST-2B may be equipped with an optional
humidity probe. This setting prevents the mist from
activating or deactivates it if humidity is high. The
mist output will remain inactive until relative
humidity decreases below this set point.
The humidity set point is adjusted in 1% increments
from a minimum setting of 30% to a maximum
setting of 80%.
Adjusting the humidity set point:
•
rotate the selector dial to position (12),
•
rapidly rotate the adjuster dial back and forth to
enter secondary function mode,
•
rotate the selector dial to position (1).
•
rotate the adjuster dial counterclockwise to
decrease the humidity set point, and clockwise
to increase it.
The value of the humidity set point setting is
displayed on the MST-2B.
RH