Page 35
MINIMUM RAMPING
Minimum ramping is the lowest that the
ramping function can adjust the main set point
to. This is a security feature.
The minimum ramping setting is adjusted in
0.5 degree increments from a minimum setting
of 13.5°F (-9.5°C) to a maximum setting of
105.0°F (41.0°C).
Adjusting the minimum ramping setting:
rotate the Selector dial to position (12),
rapidly rotate the Adjustor dial back and forth
to enter secondary function mode,
rotate the Selector dial to position (9),
rotate the Adjustor dial counterclockwise to
decrease the minimum ramping setting,
clockwise to increase it.
The minimum ramping setting is displayed on
the ECS.
Limit
NOTE: When the main set point
temperature reaches the minimum
ramping limit, the ramping setting
(primary function 9) automatically shuts
off.
CHAPTER 3 - USER GUIDE
www.monitrol.com