Page 18
CPS-3M
ZONE 2 MAIN SET POINT TEMPERATURE
(MANUAL MODE)
The main set point establishes the target
temperature in the building. The main set point
temperature is adjusted in 0.5 degree increments
from a minimum setting of 42.0°F (5.5°C) to a
maximum setting of 111°F (44.0°C).
Adjusting the main set point temperature:
•
rotate the selector dial to position (2),
•
rotate the adjustor dial counterclockwise to
decrease the setting, and clockwise to increase
it.
The main set point temperature is displayed on the
CPS-3M.
Manual mode:
The actuator motor may be manually controlled by
adjusting the main set point to OPN or CLO,
thereby causing the air inlet to either remain fully
open or closed.
To open the air inlet:
•
rotate the selector dial to position (2), then, the
adjustor dial counterclockwise to the minimum
setting, until the display shows OPN. At that
particular moment, the air inlet is opening.
To close the air inlet:
•
rotate the selector dial to position (2), then, the
adjustor dial clockwise to the maximum setting,
until the display shows CLO. At that particular
moment, the air inlet is closing.
www.monitrol.com