background image

CM10-2 

User’s Manual 

AUTO

OFF

OFF

AUTO

ON

ON

Varifan

CM10-

www.monitrol.com

Содержание CM10-2

Страница 1: ...CM10 2 User s Manual AUTO OFF OFF AUTO ON ON Varifan CM10 www monitrol com ...

Страница 2: ...or added security against line voltage surges it is recommended that surge and noise suppression devices be installed at the electrical distribution panel Use of shielded cable for probes is recommended for protection against lightning These devices are available from most electrical supply distributors RECOMMENDATIONS The manufacturer recommends that all installation procedures described herein b...

Страница 3: ...acking 5 2 2 Mounting 5 2 3 Connection Procedure 6 2 3 1 Cabling 6 2 3 2 Connecting 115 VAC Fans 6 2 3 3 Connecting 230 VAC Fans 6 2 3 4 Connecting to a MSC or an IC control 7 2 4 Powering Up 7 USER S GUIDE 11 APPENDIX Troubleshooting 12 Specifications 13 TABLE OF CONTENTS www monitrol com ...

Страница 4: ...he control of a MSC or an IC control system resulting in a clean air environment for your livestock Small loads driving less than 0 1A such as relays heater coils or sprinkler valves may be connected to the CM10 2 The CM10 2 provides you with automated control over its two stages via the use of the MSC the IC or alternatively by manual switch control on the CM10 2 front panel Under MSC or IC contr...

Страница 5: ...lding the faceplate to the housing INSTALLATION The manufacturer recommends that the installation instructions which follow be adhered to as closely as possible and all work be performed by a certified electrician Failure to do so may void the warranty To limit the unit s exposure to noxious gases install the unit in a hallway Make certain that the unit is mounted right side up with the cable entr...

Страница 6: ...urce to the neutral of fans 1 and 2 Connect the live lead of fan 1 to terminal 2 Connect the live lead of fan 2 to terminal 4 2 3 3 Connecting 230VAC Fans Refer to figure 2 Connect L1 of the power source to terminal 1 for fan 1 and terminal 3 for fan 2 Connect the ground wire of the power source to the ground wire in the housing Connect L2 of the power source to the appropriate terminals of fans 1...

Страница 7: ...our MSC or IC manual for further connection procedures 2 4 POWERING UP Before powering up the CM10 2 attach the faceplate to the casing of the control panel using the four screws previously removed To test the unit independently of the MSC or the IC set the two toggle switches located on the front of the unit to ON Fans 1 and 2 should both operate If they do not refer to the Trouble Shooting secti...

Страница 8: ...Page 8 CM10 2 Fig 1 Main Board Connection of 115 VAC source and 115 VAC fans www monitrol com ...

Страница 9: ...Page 9 INSTALLATION Fig 2 Main Board Connection of 230 VAC source and 230 VAC fans www monitrol com ...

Страница 10: ...otes for Figures 1 and 2 Power cut and protection devices in case of overload Connect the grounding wire from the power cord to the ground terminal wire shown in figures 1 and 2 inside the housing 1 2 www monitrol com ...

Страница 11: ...ition of the toggle switches For example when the MSC or the IC sends a command to the CM10 2 for a fan to operate the corresponding LED will turn ON even if the toggle switch is in the ON or OFF position The toggle switches permit the fans to be set in one of three modes as follows OFF To turn the fans permanently off set the toggle switches to the OFF position ON To turn the fans continually on ...

Страница 12: ...toggle switches to AUTO Adjust setting of the MSC or the IC to allow fans to operate Are the fans or any other load operating The unit is OK Verify corresponding LED status on the MSC the IC and the CM10 2 Are the LEDs of the CM10 2 ON Contact your dealer for service The fans should n o t b e o p e r a t i n g V e r i f y t h e settings of the MSC or the IC Verify the low voltage cable between the...

Страница 13: ...5 HP 230V 3 4 HP 115V Fuse 20A STAGE 2 Solid state relay 10 AMP 115 230 VAC 50 60 Hz Min rating 100mA 230V Min rating 50mA 115V 1 5 HP 230V 3 4 HP 115V Fuse 20A SPECIFICATIONS Storage Temperature 32 to 158 F 0 to 70 C Operation temperature 32 to 122 F 0 to 50 C Weight 1 7 lb 0 7kg Dimension 7 75 x5 75x4 196x146x101mm www monitrol com ...

Страница 14: ...Page 14 CM10 2 NOTES www monitrol com ...

Страница 15: ...htning or any other natural disaster Any unauthorized work modification or repair on this product automatically voids the warranty and disclaims the manufacturer from all responsibility The manufacturer assumes only those obligations set forth herein excluding all other warranties or obligations This warranty stipulates that in all cases the manufacturer shall be liable only for the supply of repl...

Страница 16: ...MAV CM10 2 VER 1 0 June 2004 www monitrol com ...

Отзывы: