66
17 December 2012
02.9703.0001 A
FAIL
Test Fail
Indicates that a test has failed.
Fixt Hrs
Fixture Hours
Displays total number of hours luminaire has been powered on.
Fixture
Fixture
Accesses luminaire information such as serial number, software version, and
total operation hours. Also accesses recalibration and download options.
Green
Green LED
Specifies Green (intensity) parameter for manual control (
Manual
).
Int Level
Intensity Level
The Intensity Limiter is used to match overall output level of multiple VLX wash
luminaires if desired. The Intensity Limiter default is 100% and is adjustable by
the user. For example, if a fixture’s Intensity Limiter is set to’80’, a value of
100% from a desk will only output 80% of the fixture power (as determined by
the VLX Operation Mode - Normal, Quiet, Constant Fans or Level Light)
Inv Pan
Invert Pan
Reverses pan action for special focus requirements.
Inv Tilt
Invert Tilt
Reverses tilt action for special focus requirements.
LED Correction
LED Calibration
Level
Sets LEDs to factory calibration level.
LED Fans
LED Fan Test
Specifies one of luminaire’s six fans for status (or current state) information.
LED Setup
LED Operational
Settings
LED settings/operation of power level or calibration.
LED Status
Current Status of
LED
Specifies one of luminaire’s seven LEDs for status (or current state) informa-
tion.
LED Temps
LED Operational
Temperature
Measures temperature associated with LED operation - displays in degrees
Celsius
Level Light
Fixture Mode
Luminaire setup is in set to Level Light mode by user. This mode maintains a
reduced LED output to keep various fixtures from operating at different levels
depending upon thermal situations. The fans will run full speed, regardless of
junction temperatures.
Linear
Dimming Curve -
Linear
Sets dimmer operation to standard linear dimming curve.
See also, "Square
Law"
Manual
Manual
Accesses options for luminaire mechanism control by entry of data values.
Mode 1
Mode 1 DMX
Operation
See “DMX Mode 1 Channel Mapping (Normal Operational Mode)” on
page 22.
Mode 2
Mode 2 DMX
Operation
See “DMX Mode 2 Channel Mapping (Enhanced Operational Mode)”
on page 25.
Mode 3
Mode 3 DMX
Operation
See “DMX Mode 3 Channel Mapping (Individual LED Engine Con-
trol)” on page 29.
Mode 4
Mode 4 DMX
Operation
See “DMX Mode 4 Channel Mapping (Enhanced Individual LED
Engine Control)” on page 33.
Movement
Movement
Enables or disables pan and tilt movement.
Normal
Fixture Mode
(Default) Luminaire setup is in normal fan and LED operational mode. This
mode operates the luminaire’s fans according to the LED's junction tempera-
ture. Fans will vary in speed according to thermal readings by MCB.
OFF
Off
Turns off a function.
Off Time
Display off time
Shows the automatic shut-off time for the menu display.
OK
Okay
Indicates calibration has completed and no errors have occurred.
OK?
Okay?
Prompt for pressing [Enter] before an action is executed.
Table 4-2: Menu Function Definitions (Continued)
Display
Definition
Purpose
Содержание VLX3
Страница 1: ......
Страница 13: ...FOREWORD 02 9703 0001 A 17 December 2012 xi...
Страница 14: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL xii 17 December 2012 02 9703 0001 A...
Страница 36: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 20 17 December 2012 02 9703 0001 A Notes...
Страница 84: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 68 17 December 2012 02 9703 0001 A Notes...
Страница 97: ......