I
NSTALLATION
: I
NSTALLATION
P
ROCEDURES
02.9703.0001 A
17 December 2012
17
Floor Mounting the Luminaire
The luminaire enclosure is sufficient to stabilize the luminaire in a floor
installation, provided that the mounting surface is flat and sturdy. Also, the area
around the luminaire must be free of debris and moisture.
Connecting Data and Power
A maximum of 32 luminaires may be connected in any one DMX data link.
Note:
This maximum limit applies to the luminaire "daisy chain" only. Your system or console may
require fewer luminaires on a single data link path. Consult your console documentation for more
information.
To connect power and data:
Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN
connectors of remaining luminaires in link.
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector.
(Luminaires and other devices on the same DMX chain may not function properly without
termination.)
Step 4. Connect AC input cable connector to fixture before connecting to power input source or
energizing power cable.
WARNING:
DO NOT connect or disconnect energized power cable at fixture (under load). Turn off
circuit breaker (or completely de-energize circuit) before connecting or disconnecting power cable at
fixture. Power is only removed from the fixture by disconnecting power cable from source or turning
off source circuit breaker.
Step 5. Dress AC input and data cables and secure them so they do not interfere with luminaire head
and yoke movement.
Step 6. Be sure pan and tilt locks are disengaged (refer to
“Luminaire Overview” on page 7
for
details) to allow full head and yoke movement.
Figure 2-6: Connecting Power and Data
Data In
Termination
Data Thru
AC In
AC In
AC In
Data Thru
Содержание VLX3
Страница 1: ......
Страница 13: ...FOREWORD 02 9703 0001 A 17 December 2012 xi...
Страница 14: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL xii 17 December 2012 02 9703 0001 A...
Страница 36: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 20 17 December 2012 02 9703 0001 A Notes...
Страница 84: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 68 17 December 2012 02 9703 0001 A Notes...
Страница 97: ......