11
For single-phase power at 240 volts RMS:
Connection
Pin
AC Neutral
N
AC Line
L
Ground(Earth)
G
WARNING: It is not recommended to power any VARI
LITE luminaire from a dimmer
- even in 'NONDIM' mode. Dimmer and non-dim modules are not suitable sources of
power because their output modifies the AC wave form. This may work for a short time, but
will eventually result in power problems, luminaire mis-operation and/or failure and may
void the luminaire’s warranty.
DMX Termination Connector
A DMX termination connector is required at the last luminaire (or "far end of the line") to
prevent signal reflections. Signal reflections may cancel out the signal at certain line lengths,
resulting in errors. The terminator is also necessary for software downloads and running
tests on multiple luminaires. To construct your own connector, you will need the following
components:
5-pin, male XLR connector.
Note:
A DMX termination connector assembly is available as an accessory from Vari-Lite.
VARI