14
Troubleshooting.
Smoke enters the room:
•
Not enough draugh in the chimney.
•
Inspect the smoke pipe or the chimney for blockage.
•
Clean the inside of the stove removing soot from the upper vermiculite / smoke
(Deflector) plate.
•
Make sure the hight of the chimney is correct.
The glass or the chimney soot up:
•
The wood is too moist.
•
Not enough secondary air is applied to the combustion process.
•
You may have shut off the supply of ignition air too aerly when lightning up the stove.
•
There always have to be clear flames in the combustion chamber.
The heat is emitted from the stove:
•
The wood is too moist (all energy goes into drying it) or of a poor quality.
•
Inspect the position of the smoke plate and make sure there is free passage for the
smoke.
•
The amount of combustion(secondary air) air is not enough.
Combustion is too intense:
•
Gaskets in the door or the ash-pan are no longer tight and need replacement.
•
The chimney draugh is too strong—apply a valve in the chimney.
•
Inspect that the ignition air is closed.
The Shake grate is stuck:
•
Inspect the grate for jammed wood, nails or the like.
•
Make sure the lever is placed correctly
.
Recycling
Packing
The packing is 100% recycleable.
Ceramic Glass
Ceramic glass tobe deposited at the local recycling center and sorted together with pottery and
porcelain.
Vermiculite
Vermiculite plates from the stove must be returned to the local recycling center.