H
Steam Handle
Vapor On/ Off 12-V
Infinitely Variable Vapor
Volume Control
Water Fill With
Safety Cap
Pressure Gauge
On/Off Power
Heating 110-V Element
Green Ready Light
Red Light Low Water
Indicator
L
E
F
D
Reset Breaker Button
J
Tank Drain Plug
Located Center
Bottom
K
A
B
I
C
Steam On/Off
12-V Switch
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
Mono-Bloc Connection For
Flexible Steam Hose
Make sure
E
Pressure Gauge is on zero. Press down on cap
A
and turn
counterclockwise to remove cap.
Fill unit with warm or hot clean water.
NEVER ADD ANYTHING BUT CLEAN WATER
TO THE TANK
Close
A
Safety Cap. Turn clockwise. Finger Tighten only!
DO NOT OVERTIGHTEN
CAP!
Plug electric cord into a properly grounded 110-V outlet.
Press
B
On/Off 110-V Power Switch to "on" position
Press
C
12-V Steam Button to "on" position
Press
D
Reset breaker button located on top of machine
When
H
green light is on, machine is ready for operation. While cleaning, pressure will
drop and green light will go off, this is normal operation.
When
I
red light comes on, water must be added to the unit. Turn power button off.
With
C
Steam Button on, press
L
Steam Handle Switch until all pressure is released
from tank. When
E
pressure gauge shows zero pressure, remove pressure cap.
DO
NOT OPEN CAP UNDER PRESSURE!
Unplug the unit
To refill, follow steps 1 - 5.
VaporLux 5000 UL