background image

Ø

The steam symbol      will illuminate
on   the   console   signaling   the   Blue
Evolution is in 

Steam Mode

.

Ø

This symbol

 will start flashing, 

signaling the boiler is heating.

Ø

Squeeze the 

RED

 trigger on the hose

handle to release steam.

Ø

Steam Pressure can be increased (+)

or decreased (-) on the side of hose
handle.

Steam Pressure Setting:

Ø

3 – Heavy soil or grease

Ø

2 – Recommend for most cleaning   

Ø

1 – Light soil / Delicate surfaces

Steam Pressure

 Adjustment

The   wet/dry   vacuum   on   the   Blue 
Evolution can be used independently or 
with the 

Steam 

and

 Extraction

.  Utilize 

the vacuum to reduce surface moisture 
while cleaning.  

Ø

Fill the collection tank with water
before using the vacuum (see page 8).

Ø

Do not exceed the 

GREEN

 max fill

line on the tank.

Ø

The vacuum has three suction
settings indicated by the color of the
LED light on the console.

Ø

Suction can be increased (+) or
decreased (-) on the side of hose
handle.

Green 

= Low Suction

Orange 

= Medium Suction 

Red 

= High Suction 

The   Blue   Evolution   vacuum   tank   can 
hold 

½

 gallon of water.   If you exceed 

this amount the suction will stop and the 
LED will blink.

Ø

Activate the 

Vacuum

 by

pushing the       symbol on 
the hose handle

This symbol        will flash during 
operation indicating the Blue Evolution 
is reheating.

Steam  Trigger

         Steam

Vacuum

9

Look foward to it.

Start-up steam with hot water module

Start-up suction

The soaking effect and, thus, cleaning performance can be 

increased for heavy soiling by switching the hot water mo-

dule to steam.

INFO:

Do not use on sensitive surfaces or materials.

Switching on “hot water module”

Press button 

C

on the control panel to activate the hot wa-

ter module. The symbol 

N

 on the display begins to flash.

Pressing button 

T4

on the handle for the hot water module 

switches the function on and symbol 

N

on the display stays 

illuminated.
Always use button 

T4

on the handle to switch the hot water 

module on and off.

T3

T4

The  "hot  water  module"  flow-through  can  be  adjustet, by 

pressing the button 

C

in 10% increments. This is indicated 

between 010 an 100 in the display.
Display shows 010 =   10% minimum amount of hot water
Display shows 100 = 100% maximum amount of hot water

Suction

Press button 

B

 on the display to activate suction.

LED 

D

 for suction turns red. (Suction mode 3 = max.)

Press button 

T3

 on the handle to switch on suction.

Briefly press button 

T5

+ or 

T5

on the side to vary suction 

power.

MIN  = LED 

D

 turns green

MED = LED

D

turns orange

MAX = LED

D

turns red

Press button 

T3

briefly to turn suction off again.

INFO:

As there is liquid in the hose and in the extension pipes du-

ring suction operation, the sucker should not disconnected 

immediately after cleaning finishes.
A short delay (approx. 30 seconds) is required.

T5

B

D

C

N

1

3

Steam Pressure 

setting

Blue Evolution is Ready when:

Ø

Temperature 

330 

Ø

It will take 10 minutes for the
steamer to heat and reach working
temperature

WARNING:  STEAM GENERATED BY THE BLUE EVOLUTION IS EXTREMLY HOT AND MAY 
CAUSE INJURY IF THE STEAM COMES IN DIRECT CONTACT WITH THE SKIN OR EYES.  USE 
AS ONLY AS DIRECTED BY THE THIS MANUAL AND ONLY AIM THE STEAM HANDLE AT THE 
CLEANING AREA.

Содержание Blue Evolution

Страница 1: ...User Manual 1781 Anchor Avenue Petersburg VA 23803 800 758 3141 1 ...

Страница 2: ...2 ...

Страница 3: ...______ 11 Descaling ________________________________________________________ 13 Notices __________________________________________________________ 16 Warranty Repair _________________________________________________ 17 117 PSI 338 F 15 x 28 x 37 W x L x H 61 Pounds 10 ft 10 ft Technical Data Steam Max pressure Boiler Max temperature Dimensions in Weight Power cord Length Hose Length Tank Capacitie...

Страница 4: ...odule Start up suction performance can be g the hot water mo erials Suction Press button B on the display to activate suction LED D for suction turns red Suction mode 3 max Press button T3 on the handle to switch on suction B D C Look foward to it uction B D ON OFF VACUUM EXTRACTION Exhaust Cover Iron not included Collection Tank LED Colors Green Low Vacuum Orange Medium Vacuum Red High Vacuum 4 B...

Страница 5: ...ration Filling the filter bowl Your appliance is fitted with a hygienic water filter You must fill the filter bowl with water before starting in order to bind the extracted dirt in the water and to clean the suctioned air in the water bath as well Loosen the clips on the right and left of the filter bowl and remove from its slot Open the cover on the filter bowl by pushing off the rele vant clips ...

Страница 6: ...le Ø Suction can be increased or decreased on the side of hose handle Green Low Suction Orange Medium Suction Red High Suction The Blue Evolution vacuum tank can hold gallon of water If you exceed this amount the suction will stop and the LED will blink Ø Activate the Vacuum by pushing the symbol on the hose handle This symbol will flash during operation indicating the Blue Evolution is reheating ...

Страница 7: ...he button on the hose handle Vacuum Extraction Extraction Shut Down After Each Use It is important to clean accessories and brushes Ø Run the vacuum for 30 seconds to remove any water from the hose Ø Use hot soapy and water to clean brushes and nozzles Ø Empty and use hot soapy water to clean the collection tank and remove all debris Ø If using the Blue Evolution on an extremely dirty or greasy su...

Страница 8: ...m suction hos socket until you hear the click of the safety hook To remove the hose from the appliance press re ton A and pull on the connector A Ø Remove by pulling latches out located on the sides of the tank and slide off Ø Remove the lid and fill the tank with water to the GREEN fill line Ø Secure the lid to the tank before re installing Ø To install the tank pull out the latches and slide tan...

Страница 9: ...0 _______________________________________________________ _______________________________________________________ _______ Short Spot Jet Nozzle Part 9612 Long Spot Jet Nozzle Part 9613 Suction Nozzle Part 8010 3 Round Brush Part 7109 1 Nylon Part G0018 1 Brass Part G0126 1 Steel Part G0125 Accessories ______________________________________________________ Hose Part 9618 Extension Wands Part 9615 A...

Страница 10: ...gs on the steam spout Cleaning care and maintenance of accessories Pos 1 Pos 2 rings Pos 3 Entkalkungsanleitung B Care of accessories It is essential to clean accessory parts after use to maintain the appliance Te connections on the extension pipes and the safety suitable lubricant or silicone spray as required This will make it Checking the O rings To avoid damage to the appliance or accessories ...

Страница 11: ...he steam reservoir tank Ø Refill the steam reservoir tank Ø Push the ON OF button on the console to reset No Vacuum Suction Warning alarm goes off Ø Empty and clean the collection tank Ø Refill with water to the green fill line No Vacuum Suction No warning signals Ø Collection tank lid is not attached correctly Ø Lid must sit flush on the and locked into position Ø It s helpful to attach the lid t...

Страница 12: ...12 ...

Страница 13: ...D D turns green MED LED D turns orange MAX LED D turns red Press button T3 briefly to turn suction off again INFO As there is liquid in the hose and in the extension pipes du ring suction operation the sucker should not disconnected immediately after cleaning finishes A short delay approx 30 seconds is required T5 B D C N 13 Step 1 Drain the Steam Extraction and Boiler Tanks Drain plugs are locate...

Страница 14: ... the boiler tank for at 15 minutes Step 3 Clean the Descaling Sensor Attached to the boiler cap is the water fill sensor The sensor must be cleaned each time the Blue Evolution is descaled Remove the sensor and soak in remaining descaling solution until all minerals are removed Rinse sensor with tap water and replace cap and tighten by pushing down and turning clockwise Step 4 Descale the Extracti...

Страница 15: ...ution allowing the water to be pulled into the boiler tank When you hear the low water alarm turn OFF Remove all drain plugs emptying the water in the tanks Replace drain plugs Ø Boiler plug is tight when stops turning Ø The blue steam and yellow extraction tank plug will have a snug fit and NOT stop turning Replace exhaust cover Refill the extraction and steam tanks with tap water Blue Evolution ...

Страница 16: ...freezing temperatures while not in use Ø DO NOT store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance ELECTRICAL CONNECTIONS The steam cleaner uses 110 Volts and will pull 13 1 Amps It should be the only appliance plugged into an outlet Ø Use only a 12 gauge 15AMP rated or higher extension cord Ø Any alteration of electrical cord supply on this steam c...

Страница 17: ... customer service representative will explain how you must package and ship your Steamer to prevent further damage RETURN PROCEDURES Prior to returning the product s you must obtain a Return Merchandise Authorization RMA by calling 800 758 3141 No returns will be accepted without RMA When packing the Steamer you must use the original packing material to prevent damage in shipping Make sure you inc...

Страница 18: ...rk environment increasing productivity and reducing sick days Lockers Mats Gym Equipment Steam kills mold and germs caused by sweaty athletes Equipment Lockers and Saunas Kills viruses and germs found on workout equipment and gym floors Toys Playgrounds Beds The Blue Evolution can clean all areas where kids pass germs Extreme cleaning can reduce sick days for kids and employees Seats and Floors Th...

Отзывы: