Vante ® Model 4160
16
4.
Cool temperature adjustment buttons:
use the ▼ and ▲ buttons to
adjust the target temperature.
5.
User Password Set:
press
set
to enable, disable, or change the user-level
password. The user-level password must meet the following criteria:
Contain at least 8 characters
Contain at least one numeric digit
Contain at least one non-alphanumeric symbol
6.
Admin Password Set:
press set to change the administrative password.
When changing the administrative password, the user is required to enter
the new password twice. Press cancel to close the password entry
keyboard and revert to the previous administrative password.
7.
Reset:
press this button to revert all system recipes and system settings to
default values. When you press reset, all passwords are cleared. Press the
check
button to confirm a system reset; press the
X
button to cancel.
8.
Back:
press this button to navigate back to the main control screen.
9.
Cancel:
press this button to cancel any changes in the system settings
screen and revert to previous settings.
10.
Apply:
press this button to implement any changes in the system settings
screen.
NOTE:
Change any field to enable the
cancel
and
apply
buttons. Press either
cancel
or
apply
to disable these buttons.
Once changes are applied, the user can no longer use the
cancel
button to revert to
previous settings.
2.6.
Errors
2.6.1.
If the system loses power during a cycle, the screen displays an error message
once power is restored. See Cycle Interrupt Indicator on page 14.
2.6.2.
If the heating elements fail to ramp up to the target temperature during the
process seal time, or if the sealing head temperature exceeds the maximum
temperature tolerance, then the screen displays a temperature error message.
Allow the sealing head temperature to drop to the cool temp, then restart the
system to clear the error.
2.7.
Air sources
2.7.1.
Internal compressor: the internal compressor is selected as the default air
source, which helps prevent system damage in case an external air source is
not connected.
2.7.2.
The sealing system is more efficient when connected to an external air source.
If your facility has an external air source, refer to Installation on page 9 for
instructions on connecting the air supply to the generator/controller. Navigate
to the system settings screen (see System settings on page 15), and switch off
internal air.
Содержание 4160
Страница 1: ...Doc No 41600833 01 Rev A1 INSTRUCTION MANUAL TPE TUBE SEALER Model 4160 Generator Controller...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 12: ...Vante Model 4160 4 Figure 1 2 Product labeling and components rear view Figure 1 3 Voltage and fuse labels...
Страница 15: ...Vante Model 4160 7 Figure 1 4 Sealing head with safety switch...
Страница 16: ...Vante Model 4160 8 This page intentionally left blank...
Страница 30: ...Vante Model 4160 22 This page intentionally left blank...
Страница 32: ...Vante Model 4160 24 This page intentionally left blank...
Страница 36: ...Vante Model 4160 28 This page intentionally left blank...
Страница 38: ...Vante Model 4160 30 This page intentionally left blank...