Vante ® Model 4160
9
2.
Procedures for Use
2.1.
Installation
2.1.1.
Remove the sealing system and components from their shipping containers.
Visually inspect all components for obvious damage. Contact Vante if any
components are damaged. If possible, retain shipping containers and packing
materials for future use.
2.1.2.
Set up the generator/controller on a flat secure surface near the area of
intended operation.
NOTE:
Leave space to the rear of the unit to allow easy connection and disconnection of
the AC cord. Secure the cord to prevent tripping hazards.
2.1.3.
Connect the sealing head to the generator/controller by aligning the notch of
the plug (the 8 foot cable) with the receptacle. Turn the ring on the male
connector clockwise until the connectors lock.
2.1.4.
Firmly press the air connector into the matching connector on the front of the
controller until it snaps and locks into place.
CAUTION:
Never power on the generator/controller without a sealing head attached.
Connect and disconnect the sealing head while the generator/controller is powered
off. Never connect or disconnect a sealing head while the generator/controller is
on.
2.1.5.
Connect the 3/16″ outer diameter air supply tube (included) to the back of the
generator/controller by pressing the tube firmly into the labeled, orange, tube
fitting. Connect the other end of the air supply tube to a compressed air
source. (80 – 90 psi filtered air is optimal. See Table 1.1 on page 1 for air
supply requirements.) If external air is not available, the unit has an internal
compressor for low pressure air.
CAUTION:
Incorrect air pressure, or improper air supply connection, can damage the
equipment and cause poor sealing results.
2.1.6.
Connect the AC cord to the power input receptacle on the back of the
generator/controller. Plug the cord into an appropriate power source. Refer to
the ratings on the sealer label.
NOTE:
Verify that the power cord plug is compatible with the outlets in your facility. If
the power cord is not compatible, contact Vante.
2.1.7.
Power on the system by switching the power switch on the back of the
generator/controller to on ( | ).
Содержание 4160
Страница 1: ...Doc No 41600833 01 Rev A1 INSTRUCTION MANUAL TPE TUBE SEALER Model 4160 Generator Controller...
Страница 2: ......
Страница 4: ...This page intentionally left blank...
Страница 12: ...Vante Model 4160 4 Figure 1 2 Product labeling and components rear view Figure 1 3 Voltage and fuse labels...
Страница 15: ...Vante Model 4160 7 Figure 1 4 Sealing head with safety switch...
Страница 16: ...Vante Model 4160 8 This page intentionally left blank...
Страница 30: ...Vante Model 4160 22 This page intentionally left blank...
Страница 32: ...Vante Model 4160 24 This page intentionally left blank...
Страница 36: ...Vante Model 4160 28 This page intentionally left blank...
Страница 38: ...Vante Model 4160 30 This page intentionally left blank...