42
VMM3120
Power
The following table provides specifications for the VMM3120's sensor power
output:
Sensor Power Specifications
Item
MIN
NOM
MAX
UNIT
Input voltage range (5 V output)
7
-
32
Input voltage range (8 V output)
10
-
32
V
Over-voltage
-
-
36
V
Output voltage range (5 V)
4.74
5.02
5.30
V
Output voltage range (8 V)
7.63
8.09
8.56
V
Output voltage accuracy
-
-
6
%
Output current
0
-
300
mA
5.2.1.1. Sensor Power Fault Responses
SENSOR_SUPPLY
is designed to survive short-to-battery, short-to-ground, and over-
current events. If these events occur, the circuit will recover as described in the
following table:
Sensor Power Fault Recovery
Event
Recovery
Short-to-battery
(sensor voltage = battery voltage)
Sensor voltage recovers when the short is removed.
Short-to-ground
(sensor voltage = ground)
Sensor voltage recovers when the short is removed.
Over-current
(sensor voltage = ground)
Sensor voltage recovers when the over-current
condition is removed.