OWNER’S MANUAL

OPERATING
GUIDELINES AND
MAINTENANCE
INSTRUCTIONS

 WARNING: The logs can be

hot. Handle only when cool.

PILOT ASSEMBLY
ADJUSTMENT

Turn the adjustment screw marked pilot
clockwise to decrease or counterclockwise
to increase the flame to proper size (see
Figure 31).

Do not remove the adjustment screw.

BURNER FLAME
ADJUSTMENT

Figure 31 - Correct Pilot Flame Pattern

The main burner flame should be a blue flame
somewhere between a long blue flame and a
short, sharp flame that tends to blow off the
ports.  If flame is short, very sharp or blowing,
the burner air shutter should be closed enough
to obtain a long blue flame (see Figure 32).
Long yellow flame produce excess carbon
monoxide and could cause sooting.

TO SHUT OFF

1.

For temporary shut-off, turn off remote
control wall switch. Pilot burner will
remain lit, ready for return to ON.

2.

For long term shut-off, depress the gas
valve cock valve, located under the fire-
box, turn clockwise to the OFF position.

Figure 32 - Burner Flame Patterns

CORRECT

INCORRECT
CLOSE
SHUTTER

INCORRECT
OPEN
SHUTTER

Short, Sharp,
Blowing Flame

Long, Blue Flame
with Yellow Tips

Long, Uneven,
Yellow Flame

3/8" Min.

Thermopile

Pilot Burner

1.

Upon completing your gas line connec-
tion, a small amount of air will be in
the lines. When first lighting the appli-
ance it will take the appliance a few
minutes to purge the air. Once purging
is complete, the pilot and burner will
light and operate as indicated in the
instruction manual. Subsequent light-
ing of the appliance will not require
such purging.

1.

When lit for the first time, the appli-
ance will emit a slight odor for an hour
or two. This is due to the “curing” of
the logs and “burn-in” of internal paints
and lubricants used in the manufactur-
ing process.

2.

Keep control compartment, logs burn-
ers, and area surrounding the logs
clean by vacuuming or brushing at
least twice a year. Do not vacuum the
mineral wool located in the front of
the burner assembly.

3.

Always turn off gas to pilot before
cleaning. For example relighting, refer
to the lighting instructions.

4.

A qualified field service technician should
inspect the appliance and venting system
before use or at least annually.

5.

Always keep the appliance area clear
and free from combustible materials,
gasoline and other flammable vapors
and liquids.

6.

Never obstruct the flow of combustion
and ventilation air. Keep the front of
the appliance clear of all obstacles and
materials.

7.

Never leave children unattended when
the appliance is operating.

 WARNING: Turn off gas and

electrical power before servicing
appliance. It is recommended that
a qualified serviceman perform
these checkups at the beginning
of each heating season.

In order to properly clean the burner and
pilot assembly remove the logs exposing the
burner and pilot assembly.

CLEANING BURNER AND
PILOT

Clean all foreign materials from the top of
burner and from bottom panel below.  Check
to make sure that burner orifice is clean.
Visually inspect pilot. Brush or blow away
any dust and lint accumulations. If pilot
orifice is plugged, disassembly maybe re-
quired to remove any foreign materials from
orifice and/or tubing. When appliance is put
back in service, check pilot flame patterns
(see Figure 31).

MAINTENANCE

Содержание VGL850N

Страница 1: ...mediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ...2 572mm 9 5 8 244mm 27 689mm 10 3 4 273mm Left Side 9 3 4 248mm Right Side 13 330mm 2 3 8 60mm 32 813mm 33 13 16 859mm HEARTH AREA DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW FRONT INSIDE VIEW Fig...

Страница 3: ...warranty will be voided by and DESA disclaims any responsibility for the following actions A Modification of the appliance or any of the components B Use of any component part not ap proved by DESA i...

Страница 4: ...be yondanoutsidewall thiswouldalsoreduce the cutting of joists roof rafters and such Check local codes for any restrictions Projected installations can extend any distance into the room A projection...

Страница 5: ...ppliance see Figure 17 page 9 Figure 7 Rough Opening for Installing in Wall Figure 8 Rough Opening for Corner Installation 41 7 8 1061mm 15 381mm 36 1 4 921mm 59 1 4 1505mm 29 5 8 752mm 21 3 16 538mm...

Страница 6: ...vertical system height Codes also allows only one offset in the total system when at 60 de grees or greater The total vertical height in thisexamplerepresentstheminimumheight of 8 feet and therefore...

Страница 7: ...c tion see Figure 10 VENTING INSTALLATION Continued If venting horizontally through a side wall becomes necessary a listed thimble ap proved for use with B type vent must be used Check with your local...

Страница 8: ...ach the terminal wires to the battery see Figure 14 8 Replace access panel Place top of ac cess panel into opening and slide up Push bottom of access panel in and slide down to install Figure 13 Insta...

Страница 9: ...ncoming Black Iron Gas Line Flexible Gas Line 1 Provided Can Be Extended Out from 3 Sides Typical Exterior Wall Gas Shut Off Installation CAUTION Do not kink flex ible gas line DESA recommends that a...

Страница 10: ...t log piece into the notches on the right side of the front and rear logs see Figure 25 NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner could cause performance proble...

Страница 11: ...s Ifthisisthecase pleaserequest help from someone else CAUTION For use with glass doorscertifiedwiththeappliance only CAUTION Do not operate theappliancewiththeglassdoor removed WARNING Children and a...

Страница 12: ...GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instru...

Страница 13: ...will not require such purging 1 When lit for the first time the appli ance will emit a slight odor for an hour or two This is due to the curing of the logs and burn in of internal paints and lubrican...

Страница 14: ...rgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier WIRING DIAGRAM Pilot Burner Pilot Gas Line Thermopile Note Use only original replacement parts This will prot...

Страница 15: ...or sensor not gen erating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in the PILOT posi...

Страница 16: ...lot lights turn off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the improper lighting and a longer purge period is recommended If pilot will not light che...

Страница 17: ...f page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner...

Страница 18: ...485 105860 02 If in need of replacing have a qualified technician replace it GAS CONTROL VALVE Natural 14512 105861 01 Propane LP 14513 105861 02 If in need of replacing have a qualified technician re...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...he responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...