OWNER’S MANUAL

COMBUSTION AIR KIT
MODEL VAKGL (OPTIONAL)

The outside air kit may be installed on the
right side of the fireplace only.  The vent can
be installed through the outside wall or a
ventilated crawl space.  The handle to oper-
ate the damper door for the outside air inlet
will be located behind the burner valve
access door when the kit is installed (see
Figure 26). Pull the handle to open or push
to close.

APPLIANCE ENCLOSURE

Before finishing the enclosure around the
appliance, inspect all joints around the outer
surround. Any gaps between the nailing
flanges and the framing should be sealed with
non-combustible insulation or caulking.

If the appliance is mounted on a raised
platform, it must be a continuous surface
and not on blocks without a solid surface.
This will prevent the entry of cold air by
means of conduction through the total bot-
tom of the appliance. (see Figure 27).

 CAUTION: Air inlet ducts are

not to terminate in attic space.

To replace, insert top door pins into spring
clips located on the top face. Make sure pins
are properly secured to the clips. As you
hold top portion in place, swing bottom of
door towards bottom face until the bottom
door pins clear the flange and then insert the
lower pins into the locating slots until seated
(see Figure 28).

Note:

 some adjustment maybe required in

order to align door pins to clip (top) and
locating slots (bottom).

This can be done by loosening the screw
securing both spring clip and pivot plate and
sliding it to the proper location.

GLASS DOOR REMOVAL
AND REPLACEMENT

To remove, hold the glass door firmly at
handles and evenly push straight up until
bottom pins are free from location slots
(see Figure 28). Slightly swing door to-
wards you. At this point, while maintain-
ing glass door secured at one handle, grasp
the side of glass panel for better grip and
slightly pull glass door down to free top
pins from spring clips.

Note:

 Glass door may be heavy for some

individuals. If this is the case, please request
help from someone else.

 CAUTION: For use with glass

doors certified with the appliance
only.

 CAUTION: Do not operate

the appliance with the glass door
removed.

 WARNING: Children and

adults should be alerted to the
hazards of high surface tempera-
tures and should stay away to
avoid burns or clothing ignition.
Young children should be super-
vised when they are in the same
room as the appliance.

• When ordering replacement or accessory

items please have your appliance’s model
name or number and the part number of
the item (s) you are ordering ready. The
model name or number for your particu-
lar appliance may be found on the rating
plate  located inside the appliance.

• Refer to the parts list and diagrams

when ordering replacement parts for
your appliance.

• Repair parts or accessory items may be

bought from your local representative.

• All product specifications are subject to

change without notice.

 WARNING: Installation and

repair should be done by a quali-
fied service person. The appliance
should be inspected before each
use and at least annually by a quali-
fied service person.  More frequent
cleaning may be required due to
excessive lint from carpeting, bed-
ding material, pet hair, etc. It is
imperative that the control com-
partments, burners, and circulat-
ing air system be kept clean.

Figure 26 - Air Kit Handle Location

Air Kit Handle

Side
Framing

Side
Framing

Caulk Here

Pack Insulation

Figure 27 - Sealing Between Appliance
and Framing

INSTALLATION

Continued

Spring Clip

Locating Slot

Figure 28 - Removing Glass Door

Instructions for the installation of the gas kit
are included with the glass door package.
Use of any other glass door assembly not
tested with the VGL850 series models may
constitute a fire hazard and will void the
DESA International warranty.  Please read
and follow the maintenance instructions for
your glass doors as outlined below.
• Never use an abrasive material to clean

the glass. Use a rag and a liquid cleaner.

• Never clean the glass while they are hot.
• Always operate the appliance with the

glass door in place. (If the glass is left
off the unit while operating hot combus-
tion gas may enter the room)

Содержание VGL850N

Страница 1: ...mediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ...2 572mm 9 5 8 244mm 27 689mm 10 3 4 273mm Left Side 9 3 4 248mm Right Side 13 330mm 2 3 8 60mm 32 813mm 33 13 16 859mm HEARTH AREA DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW FRONT INSIDE VIEW Fig...

Страница 3: ...warranty will be voided by and DESA disclaims any responsibility for the following actions A Modification of the appliance or any of the components B Use of any component part not ap proved by DESA i...

Страница 4: ...be yondanoutsidewall thiswouldalsoreduce the cutting of joists roof rafters and such Check local codes for any restrictions Projected installations can extend any distance into the room A projection...

Страница 5: ...ppliance see Figure 17 page 9 Figure 7 Rough Opening for Installing in Wall Figure 8 Rough Opening for Corner Installation 41 7 8 1061mm 15 381mm 36 1 4 921mm 59 1 4 1505mm 29 5 8 752mm 21 3 16 538mm...

Страница 6: ...vertical system height Codes also allows only one offset in the total system when at 60 de grees or greater The total vertical height in thisexamplerepresentstheminimumheight of 8 feet and therefore...

Страница 7: ...c tion see Figure 10 VENTING INSTALLATION Continued If venting horizontally through a side wall becomes necessary a listed thimble ap proved for use with B type vent must be used Check with your local...

Страница 8: ...ach the terminal wires to the battery see Figure 14 8 Replace access panel Place top of ac cess panel into opening and slide up Push bottom of access panel in and slide down to install Figure 13 Insta...

Страница 9: ...ncoming Black Iron Gas Line Flexible Gas Line 1 Provided Can Be Extended Out from 3 Sides Typical Exterior Wall Gas Shut Off Installation CAUTION Do not kink flex ible gas line DESA recommends that a...

Страница 10: ...t log piece into the notches on the right side of the front and rear logs see Figure 25 NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner could cause performance proble...

Страница 11: ...s Ifthisisthecase pleaserequest help from someone else CAUTION For use with glass doorscertifiedwiththeappliance only CAUTION Do not operate theappliancewiththeglassdoor removed WARNING Children and a...

Страница 12: ...GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instru...

Страница 13: ...will not require such purging 1 When lit for the first time the appli ance will emit a slight odor for an hour or two This is due to the curing of the logs and burn in of internal paints and lubrican...

Страница 14: ...rgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier WIRING DIAGRAM Pilot Burner Pilot Gas Line Thermopile Note Use only original replacement parts This will prot...

Страница 15: ...or sensor not gen erating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in the PILOT posi...

Страница 16: ...lot lights turn off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the improper lighting and a longer purge period is recommended If pilot will not light che...

Страница 17: ...f page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner...

Страница 18: ...485 105860 02 If in need of replacing have a qualified technician replace it GAS CONTROL VALVE Natural 14512 105861 01 Propane LP 14513 105861 02 If in need of replacing have a qualified technician re...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...he responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...