Vanguard VGL850N Скачать руководство пользователя страница 12

12

105705

VENTED TYPE DECORATIVE APPLIANCE

VGL850 Series

®

TO TURN OFF GAS

TO APPLIANCE

1.

Turn off the wall switch.

2.

Turn off all electric power to the ap-
pliance if service is to be performed.

3.

Remove the glass door.

4.

Open control access panel.

5.

Turn gas control knob clockwise

Clockwise

 to “OFF”. Do not force.

6.

Close control access panel.

7.

Replace the glass door.

Figure 30 - Pilot

OPTIONAL REMOTE

OPERATION

Note:

 The GHRC receiver and hand-

held remote control kit must be purchased
separately (see Accessories,
 page 18). Fol-
low  installation  instructions on pages 8
and 9 of this manual.
1.

After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position. 

Note:

 The

burner may light if hand-held remote
ON button was on when selector
switch was last turned off. You can
now turn the burner on and off with
the hand-held remote control unit.

IMPORTANT:

  Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

IMPORTANT:

 Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

2.

Press the ON/OFF button to turn the
burner on and off. When turning
burner off, the pilot will remain lit.

IMPORTANT:

 To turn the pilot off,

manually turn the control knob on
the heater to the OFF position.

Thermopile

Pilot Burner

OPERATING
FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information,
column 1.

2.

Turn wall switch to the OFF position.

3.

Turn off all electric power to the
appliance.

4.

Remove the glass door.

5.

Open control access panel.

6.

Turn gas control knob clockwise

Clockwise

  to the OFF position (see Fig-

ure 29).

7.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas, STOP!
Follow “B” in the safety information,
column 1. If you don’t smell gas, go to
the next step.

8.

Turn control knob counterclockwise

C-clockwise

 to the PILOT position.

9.

Push in the knob all the way and hold
in. Immediately light the pilot manu-
ally. Continue to hold the control knob
in for about (1) minute after the pilot
is lit. Release knob and it will pop back
up. Pilot should remain lit. If it goes
out, repeat steps 5 through 9.
• If knob does not pop up when re-

leased, stop and immediately call
your service technician or gas
supplier.

• If the pilot will not stay lit after sev-

eral tries, turn the gas control knob
to “OFF” and call your service
technician or gas supplier.

10. Turn gas control knob counterclock-

wise 

C-clockwise

 to “ON”. Knob can be

turned to “ON” only if the control
knob is popped out.

11. Close control access panel.
12. Replace the glass door.
13. Turn on all electric power to the ap-

pliance.

Figure 29 - Control Knob in the PILOT
position

P

IL

O

T

ON

OFF

IN

OUT

Position Indicator

Gas Control Knob

Ignitor

Содержание VGL850N

Страница 1: ...mediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ...2 572mm 9 5 8 244mm 27 689mm 10 3 4 273mm Left Side 9 3 4 248mm Right Side 13 330mm 2 3 8 60mm 32 813mm 33 13 16 859mm HEARTH AREA DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW FRONT INSIDE VIEW Fig...

Страница 3: ...warranty will be voided by and DESA disclaims any responsibility for the following actions A Modification of the appliance or any of the components B Use of any component part not ap proved by DESA i...

Страница 4: ...be yondanoutsidewall thiswouldalsoreduce the cutting of joists roof rafters and such Check local codes for any restrictions Projected installations can extend any distance into the room A projection...

Страница 5: ...ppliance see Figure 17 page 9 Figure 7 Rough Opening for Installing in Wall Figure 8 Rough Opening for Corner Installation 41 7 8 1061mm 15 381mm 36 1 4 921mm 59 1 4 1505mm 29 5 8 752mm 21 3 16 538mm...

Страница 6: ...vertical system height Codes also allows only one offset in the total system when at 60 de grees or greater The total vertical height in thisexamplerepresentstheminimumheight of 8 feet and therefore...

Страница 7: ...c tion see Figure 10 VENTING INSTALLATION Continued If venting horizontally through a side wall becomes necessary a listed thimble ap proved for use with B type vent must be used Check with your local...

Страница 8: ...ach the terminal wires to the battery see Figure 14 8 Replace access panel Place top of ac cess panel into opening and slide up Push bottom of access panel in and slide down to install Figure 13 Insta...

Страница 9: ...ncoming Black Iron Gas Line Flexible Gas Line 1 Provided Can Be Extended Out from 3 Sides Typical Exterior Wall Gas Shut Off Installation CAUTION Do not kink flex ible gas line DESA recommends that a...

Страница 10: ...t log piece into the notches on the right side of the front and rear logs see Figure 25 NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner could cause performance proble...

Страница 11: ...s Ifthisisthecase pleaserequest help from someone else CAUTION For use with glass doorscertifiedwiththeappliance only CAUTION Do not operate theappliancewiththeglassdoor removed WARNING Children and a...

Страница 12: ...GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instru...

Страница 13: ...will not require such purging 1 When lit for the first time the appli ance will emit a slight odor for an hour or two This is due to the curing of the logs and burn in of internal paints and lubrican...

Страница 14: ...rgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier WIRING DIAGRAM Pilot Burner Pilot Gas Line Thermopile Note Use only original replacement parts This will prot...

Страница 15: ...or sensor not gen erating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in the PILOT posi...

Страница 16: ...lot lights turn off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the improper lighting and a longer purge period is recommended If pilot will not light che...

Страница 17: ...f page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner...

Страница 18: ...485 105860 02 If in need of replacing have a qualified technician replace it GAS CONTROL VALVE Natural 14512 105861 01 Propane LP 14513 105861 02 If in need of replacing have a qualified technician re...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...he responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...

Отзывы: