background image

26

106516

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

®

BHDV34NB AND BHDV34PB

1.

After lighting, let pilot flame burn for
about one minute. Turn 

gas 

control

knob on the control valve to ON posi-
tion. Turn variable control knob any-
where between WARMER and
COOLER. Slide the selector switch to
the REMOTE position. 

Note:

 The

burners may light if hand-held remote
ON button was on when selector switch
was last turned off. You can now turn
the burners on and off with either op-
tional hand-held remote control unit.

IMPORTANT:

 Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

IMPORTANT:

 Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the

burners on and off. When turning
burners off, the pilot will remain lit.

GHRCTA Series Operation:

2b. Press the AUTO/ON/OFF button on

the hand-held remote control (see
Figure 58). The lights to the left of
the button will show AUTO, ON, or
OFF.
• In the ON mode, the burners will

ignite. The heater is in manual
mode when ON is lit.

• In the AUTO mode, the thermostat

in the hand-held remote unit con-
trols the room temperature. To in-
crease the room temperature, press
the top arrow of the TEMP button.
To lower the room temperature,
press the bottom arrow of the
TEMP button. At higher settings
the heater will run longer.

OPERATING
FIREPLACE

Continued

O

FF

PIL

OT

O

N

L

O

IH

ON

OFF

REMO

TE

ON

OFF

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening
the lower louver panel on the fireplace.
Blower controls are located on the left
side of the switch bracket to the left just
inside the louver panel.

Both the GA3700 manual blower and the
DA3610TA thermostatically-controlled
blower have an ON setting and an OFF
setting. The blower will only run when the
switch is in the ON position. In the OFF
position, the blower will not operate.

Note for DA3610TA Only:

 If you are

using DA3610TA blower with optional
thermostat (wall mount or remote con-
trol) for the fireplace, your fireplace and
blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on. After the heater modulates to the pilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.

The blower helps distribute heated air
from the fireplace. Periodically check the
louvers of the firebox and remove any
dust, dirt, or other obstructions that will
hinder the flow of air.

Figure 57 - Setting the Selector Switch, Gas
Control Knob, and Variable Control Knob
for Remote Operation

Selector Switch in
Remote Position

Gas Control
Knob in On
Position

Variable
Control Knob

Blower Control Knob
(Optional Accessory)

IMPORTANT:

 This remote control

has been specially engineered to take
an air temperature sample every 5.5
minutes in the auto mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.

IMPORTANT:

 The hand-held remote

control unit must be near the heater.
Do not keep the hand-held remote
control unit too close to the heater.
The thermostat on the hand-held re-
mote control unit will heat up too
quickly and turn the heater off.

3.

To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.

IMPORTANT:

 To turn the pilot off,

manually turn the control knob on the
heater to the OFF position.

Figure 58 - Hand-Held Thermostat Remote Control Unit Selections
(GHRCTA Only)

Increases Room
Temperature in
AUTO Mode

Decreases Room
Temperature in
AUTO Mode

Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting

Shows Tempera-
ture Setting

The Log Heater
will Automatically
Cycle between
Pilot and the Heat
Setting that has
been Selected

Содержание BHDV34PB

Страница 1: ...is tance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result ca...

Страница 2: ...he glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide P...

Страница 3: ...t PIEZO IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BHDV Series Glass Door Assembl...

Страница 4: ...3 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 mm Perpendicular walls 6 152mm Floor...

Страница 5: ...ept where stated otherwise Combustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding You must install a v...

Страница 6: ...bove paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimu...

Страница 7: ...ination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of...

Страница 8: ...bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slid...

Страница 9: ...f the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At...

Страница 10: ...use with corner installation UP Horizontal Venting See information in Figure 17 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting Note Figure 16 applie...

Страница 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Страница 12: ...uired clearances air space to combus tibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the venting...

Страница 13: ...y using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold t...

Страница 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Venti...

Страница 15: ...alvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustable 7 12 Galvanized Coaxial Pipe 6 pcs D1050 7 x 6 Galvanized Coaxial Pipe 6 pcs D2000 7 x 90 Elbow 6 pcs D2010 7...

Страница 16: ...nstall this fireplace as your primary heat source If you have acentralheatingsystem youmay run system s circulating blower while using fireplace This will help circulate the heat through out the house...

Страница 17: ...see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is rece...

Страница 18: ...pt able alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply Fo...

Страница 19: ...ble gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup...

Страница 20: ...off valve see Fig ure 37 2 Open propane LPsupply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is i...

Страница 21: ...place or heat and air conditioning ducts 5 Gently remove the cover of the ther mostat from the base Grasp the sides of the cover firmly and pull to separate from the base 6 Feed the electrical wires t...

Страница 22: ...h terminal wires to a 9 volt alka line battery not included Place bat tery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 45 Installing Alkaline Battery in Hand Held...

Страница 23: ...48 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using the same method d...

Страница 24: ...4 Place log 4 small round log on the pin on the right side of front log as shown in Figure 53 5 Place log 5 small log onto the front left part of the grate making sure the notches fit over the prongs...

Страница 25: ...LO The burners will turn on and off automatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space to be heated the output...

Страница 26: ...ntrolled blower have an ON setting and an OFF setting The blower will only run when the switch is in the ON position In the OFF position the blower will not operate Note for DA3610TA Only If you are u...

Страница 27: ...e To Turn Off Gas to Appliance page 25 see Troubleshooting pages 29 through 31 Figure 59 Pilot Assembly Figure 60 Typical Flame Pattern for models BHDV34NB and BHDV34PB Thermocouple Thermopile 3 8 to...

Страница 28: ...gidity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before ea...

Страница 29: ...oose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holdi...

Страница 30: ...e burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1 Adjust the log...

Страница 31: ...t blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark...

Страница 32: ...o disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarr...

Страница 33: ...ure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges...

Страница 34: ...Oak G3004W Series Off White Paint Thehearthbasecreatesahandsomeriserfor the fireplace cannot be used with corner mantel Dimensions WxHxD 58 x61 2 x289 16 CORNER MANTEL GM200F Series Walnut Stained Har...

Страница 35: ...es installation and removal quick and easy They are designed to go at the top and bottom of the glass door on BHDV units Note Remove the plastic film covering on strips before installing on fireplace...

Страница 36: ...ND BHDV34PB ILLUSTRATED PARTS BREAKDOWN BHDV34NB BHDV34PB 48 31 3 1 2 3 4 6 6 36 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 33 32 32...

Страница 37: ...P 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner Natural 1 1...

Страница 38: ...airing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESS...