26
104025
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• Propane/LP gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane/LP gas supplier.
SERVICE
HINTS
Note:
Use only original replacement parts. This will protect your warranty cover-
age for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replace-
ment part(s), call DESA International’s Technical Service Department at
1-800-323-5190. When calling DESA International, have ready
• your name and address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane or natural gas)
• purchase date
Usually, we will ask you to return the defective part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replace-
ment part(s), call DESA International’s Parts Department at 1-800-972-7879 for
referral information. When calling DESA International, have ready
• model number of your heater
• the replacement part number
REPLACEMENT
PARTS
SPECIFICATIONS
Amity
Stove Gas Log Heater
Model SVYD18P
Variable Manually Controlled
Btu (Variable)
16,000/30,000
Type Gas
Propane Only
Ignition
Piezo
Pressure Manifold
8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
Minimum*
11"
* For input adjustment
Shipping Weight
28 lbs.
Amity
Stove Cabinet
Model SCIVF(*)
Shipping Weight
195 lbs.
(* Indicates Color Suffix Designation)