SPN 91 Speed Lever
Circuit Description
The ECM provides 5 volts power to the throttle on the
equipment, vehicle or to the speed control lever on the engine
operator panel. The throttle then returns a voltage to the
ECM that is interpreted as a commanded engine speed. If the
voltage exceeds 4.9 volts DC, or drops below 0.1 volts DC,
the appropriate FMI will set.
NOTE:
The engine will default to minimum target engine
speed if SPN 91 fault is active.
Possible FMIs - SPN 91
The possible FMIs for SPN 91 are as follows:
FMI
Description
3
Signal Voltage High
4
Signal Voltage Low/Open
26
Not for
Reproduction