4
1. TYPICAL INSTALLATIONS
Installations may vary according to the type of unit and the ports configuration (top or sides). Use the following illustrations as guidelines
to help you decide on how the unit will be installed.
All the units should be hung from the joists.
In every case, bathroom fans and a range hood should be used to exhaust stale air. Also, for homes with more than one level, we
recommend one exhaust register at the highest level.
There are 3 installation methods: Fully ducted, Central Draw Point and Simplified Installation.
NOTE: An electrical outlet has to be available within 3 feet of the unit.
1.1
F
ULLY
D
UCTED
S
YSTEM
(P
RIMARILY
FOR
HOMES
WITH
RADIANT
HOT
WATER
OR
ELECTRIC
BASEBOARD
HEATING
)
VH0099
Stale air coming from the registers located at the highest level of the
house is exhausted to the outside. Fresh air from outside is filtered and
supplied by the register located in the lowest liveable level.
Homes with more than one level require at least one exhaust register
at the highest level.
See figure at right.
1.2
C
ENTRAL
D
RAW
P
OINT
(C
ONNECTION
TO
A
FORCED
AIR
SYSTEM
)
Stale air coming from the registers located at the highest level of the
house is exhausted to the outside. Fresh air from outside is filtered and
supplied to the return (plenum) or the supply duct of the forced air unit.
See figure at right.
For this type of installation, it is not essential that the forced air system
blower runs when the unit is in operation, but we recommend it.
NOTE: Home with multiple forced air systems should have one unit on
each system.
1.3
S
IMPLIFIED
I
NSTALLATION
(C
ONNECTION
TO
A
FORCED
AIR
SYSTEM
)
Stale air is exhausted to the outside. Fresh air from outside is filtered
and supplied to the return (plenum) or the supply duct of the forced air
unit.
See figure at right.
To avoid cross-contamination and achieve the highest efficiencies, the
forced air system blower must always be ON.
NOTE: Home with multiple forced air systems should have one unit on
each system.
VH0100
VH0101