2.3 S
IMPLIFIED
I
NSTALLATION
(C
ONNECTION TO A FORCED AIR SYSTEM
)
2. TYPICAL INSTALLATIONS
Use the following illustrations as guidelines to help you decide on how the unit will be installed.
All the units should be hung from the joists.
In every case, bathroom fans and a range hood should be used to exhaust stale air. Also, for homes with more than one level, we
recommend one exhaust register at the highest level.
There are 3 installation methods: Fully ducted, Central Draw Point and Simplified Installation.
NOTE: An electrical outlet has to be available within 3 feet of the unit.
2.1 F
ULLY
D
UCTED
S
YSTEM
(P
RIMARILY FOR HOMES WITH RADIANT HOT WATER OR ELECTRIC BASEBOARD HEATING
.)
2.2 C
ENTRAL
D
RAW
P
OINT
(C
ONNECTION TO A FORCED AIR SYSTEM
.)
For this type of installation, it is not essential that the forced air system blower
runs when the unit is in operation, but we recommend it.
NOTE:
Home with multiple forced air systems should have one unit on
each system.
Stale air coming from the registers located at the highest level of the house
is exhausted to the outside. Fresh air from outside is filtered and supplied by
the register located in the lowest liveable level.
Homes with more than one level require at least one exhaust register at the
highest level.
See figure at right.
Stale air coming from the registers located at the highest level of the house
is exhausted to the outside. Fresh air from outside is filtered and supplied to
the return (plenum) or the supply duct of the forced air unit. See figure at
right.
Stale air is exhausted to the outside. Fresh air from outside is filtered and
supplied to the return (plenum) or the supply duct of the forced air unit.
See figure at right.
To avoid cross-contamination and achieve the highest efficiencies, the
forced air system blower must always be ON.
NOTE:
Home with multiple forced air systems should have one unit on
each system.
- 4 -
VH0002
VH0006
VH0007