Van Essen Diver-MOD-AS339 Скачать руководство пользователя страница 11

© July 2017 Van Essen Instruments. All rights reserved

Example: 

Description 

Function 

code 

Register 

Size 

(registers)

Data 

field 

Remark 

Read firmware version of 

Diver-MOD 

0x04 

30002 

10 

Register 30002, convert to 

string (20 characters). 

Read serial number of 

Diver-MOD 

0x04 

30012 

10 

Register 30012, convert to 

string (20 characters). 

3.2

 

Reg. 30220: Real-time Barometric Data from Diver-MOD 

The real-time data from the barometric sensor in the Diver-MOD is stored in register 30220 and 

30230. 
Example: 

Description 

Function 

code 

Register 

Size 

(registers)

Data 

field 

Remark 

Read real-time values 
barometric sensor (long) 

0x04 

30221 

Register 30221, convert to 
longs (two registers for long). 

Read real-time values 
barometric sensor (float) 

0x04 

30231 

Register 30231, convert to 
single float (two registers for 

single float). 

3.3

 

Reg. 40001: Change Slave Address of Diver-MOD 

Register 40001 contains the slave address of the Diver-MOD. The default slave address is 1. The slave 

address can be set from 1 to 247. 
Example: 

Description 

Function 

code 

Register 

Size 

(registers)

Data 

field 

Remark 

Change slave address 

0x06 

40001 

<1-247> 

Data field is new address. 
Register 40001 will take effect 

immediately. 

3.4

 

Reg. 40002: Change Baudrate of the RS485 port 

Register 40002 contains the baudrate at which the Diver-MOD operates. The default baudrate is 

9,600 bps. The data field must have a value from 1 to 8, which corresponds to the following 
baudrate: 

0 = 300 bps 

1 = 1,200 bps 

2 = 2,400 bps 

3 = 4,800 bps 

4 = 9,600 bps 

5 = 19,200 bps 

6 = 38,400 bps 

7 = 57,600 bps 

8 = 115,200 bps 

Содержание Diver-MOD-AS339

Страница 1: ...PRODUCT MANUAL Diver MOD AS339 M 11118002E Nijverheidsstraat 30 6987 EM Giesbeek The Netherlands T 31 313 880 200 E info eijkelkamp com I www eijkelkamp com...

Страница 2: ...nts B V be liable for any claim for direct incidental or consequential damages arising out of or in connection with the sale manufacture delivery or use of any product Van Essen Instruments and the Va...

Страница 3: ...by EN61326 1 2013 The product s to which this declaration relates is in conformity with the essential protection requirements of 2004 108 EC Electromagnetic Compatibility directive The products are in...

Страница 4: ...2 Get Diver Data 8 3 8 Reg 00003 Update General Diver Information 8 3 9 Reg 00004 Force to accept new connected Diver 8 3 10 Reg 00011 Start Stop Logging of Diver 9 3 11 Reg 30241 Number of Records Re...

Страница 5: ...July 2017 Van Essen Instruments All rights reserved 8 3 Baro Diver 24 8 4 Cera Diver 24 8 5 Micro Diver 25 8 6 CTD Diver 25 8 7 Mini Diver 26 8 8 Baro Diver 26...

Страница 6: ...Modbus interface through a 4 conductor cable This cable is used for power supply and data transfer The air vent ensures that the pressure inside the casing is equal to the outside air pressure The bui...

Страница 7: ...e address 0 to 247 Messages sent to the address 0 will be accepted by all Diver MODs The Diver MOD acts as a slave for the PLC PC that requests the data from each Diver MOD Up to 8 Diver MODs can be u...

Страница 8: ...0 mA and the effective current is 20 mA The stand by current of the Diver MOD is 2 mA If the Diver MOD is the last device in the RS485 network the A and B line should be terminated with a 120 terminat...

Страница 9: ...nication PDU A master addresses a slave by placing the slave address in the address field of the message When the slave returns its response it places its own address in the response address field to...

Страница 10: ...mands to Diver commands and vice versa There is no direct communication between the Modbus supervisory computer and the Diver The Diver MOD acts as a buffer between the supervisory computer and the Di...

Страница 11: ...for long 2 Read real time values barometric sensor float 0x04 30231 2 Register 30231 convert to single float two registers for single float 3 3 Reg 40001 Change Slave Address of Diver MOD Register 40...

Страница 12: ...iver MOD to get real time values i e pressure temperature and conductivity if applicable from the connected Diver The updated real time values must be read from registers 30201 30216 The type of condu...

Страница 13: ...up the Diver MOD Example Description Function code Register Size registers Data field Remark 1 Instruct Diver MOD to update general information from connected Diver 0x05 00002 1 0xFF00 Register 00003...

Страница 14: ...recorded by the Diver First set register 00001 to update this register in the Diver MOD with the most recent value Example Description Function code Register Size registers Data field Remark 1 Update...

Страница 15: ...ch parameter channel measured by the Diver the Diver serial number the monitoring point name location etc The following data is required to obtain the time series data in engineering units Start Date...

Страница 16: ...the Diver can measure temperature For all the supported Divers this is 100 C The temperature range can be read from register 30105 The returned value is a signed 16 bit integer for example 100 Conduct...

Страница 17: ...ation to convert these values to engineering units PENG PENG PDEC 30000 range reference If the pressure must be converted to a different unit then refer to Appendix C for conversion factors Temperatur...

Страница 18: ...t the general header information 2 Read channel 1 header information 0x04 30329 24 Read 24 registers starting at register 30329 to get the channel 1 header information 3 Read channel 2 header informat...

Страница 19: ...e Register Size registers Data field Remark 7 Read 2 000 Diver data records 0x04 32001 8 000 Read from register 32001 in increments of 100 registers Stop reading if one or more registers contain 0xFFF...

Страница 20: ...DI7xx CTD Diver DI27x TD Diver DI8xx 5 3 Power Consumption External supply voltage 5 to 12 V Standby current 2 mA Maximum current 10 mA 5 4 Modbus Communication RS485 half duplex single pair 300 bps...

Страница 21: ...5 Pressure Range 400 to 1100 cmH2O Accuracy 2 0 cmH2O Resolution 0 06 cmH2O 5 6 Temperature Range 20 to 80 C Calibrated 0 to 50 C Accuracy 1 C Resolution 0 2 C maximum 5 7 Environmental Storage Transp...

Страница 22: ...o accept new connected Diver UINT16 Write 00011 1 Start stop Diver immediate starting and stopping UINT16 Write 6 2 Read Only Registers For the Read input registers 16 bit registers Modbus Register Nu...

Страница 23: ...real time pressure 10 SINT32 Read 30223 30224 2 Baro real time temperature 100 SINT32 Read 30231 30232 2 Baro real time pressure FLOAT Read 30233 30234 2 Baro real time temperature FLOAT Read 30241 3...

Страница 24: ...nel 1 16 bytes STRING Read 30371 30380 10 Diver header Identification channel 2 20 bytes STRING Read 30381 30388 8 Diver header Reference channel 2 16 bytes STRING Read 30389 30396 8 Diver header Rang...

Страница 25: ...as integer valid values 1 247 UINT16 Read write 40002 1 Modbus baudrate settings as integer valid values 0 300 1 1200 2 2400 3 4800 4 9600 5 19200 6 38400 7 57600 8 115200 bps UINT16 Read write 40003...

Страница 26: ...hts reserved 21 Registers Number of Modbus Registers Description Format Properties 40109 40118 10 Set Location Code Diver 20 ASCII characters STRING Read write 40119 40128 10 Set Instrument number Div...

Страница 27: ...s reserved 22 7 Appendix C Pressure Conversion Table To convert from cmH2O to Multiply by hecto Pascal hPa 0 980665 kilo Pascal kPa 0 0980665 millibar mbar 0 980665 inch of mercury inHg 0 028959020848...

Страница 28: ...gths from 1 meter to 500 meter Part no AS2xxx xxx length in meter e g 10 meter cable is AS2010 8 2 TD Diver This Diver is manufactured using a stainless steel 316 L casing with a 22 mm diameter The TD...

Страница 29: ...shallow water levels up to 1 meter The Baro Diver samples pressure and temperature at fixed length intervals and stores these values in fixed length or continuous memory Part no DI800 8 4 Cera Diver...

Страница 30: ...and 100 m Part no DI6xx 8 6 CTD Diver Where there is a need to monitor groundwater levels and salt water intrusion injected wastewater or contamination from chemical discharges and landfill sites the...

Страница 31: ...available in the following pressure ranges 10 m 20 m 50 m and 100 m Part no DI5xx 8 8 Baro Diver This Diver measures atmospheric pressure and is used to compensate for the variations in atmospheric pr...

Отзывы: