ENGLISH
MD 950
/ NanoPak
Changes
Chapter 5
Page GB 39
9.694.038
V 4.02
5.2 TraceLog (logbook)
This logbook contains the temporary recording of various completed actions, events and faults
that have occurred on the device.
These recordings are only viewable while the device is switched on, however if a USB stick is
connected for the DataMatic function, the data are stored as an add-on to the DataMatic data
on it in the event of a date change and during the switch-off process.
For reliable data transfer, the device must switch itself off after pressing the
Power off button and once the shut-down period of one minute has elapsed.
No "EMERGENCY STOP" must be carried out by holding the Power off button.
5.2.1.1 The display menu
5.2.1.2 Interpretation of entries
State
Date and time
Event
T
F
v
OK
10.01.2019 15:31:53
Change DataMatic
Sealing temperature at
this time
Contact pressure at
this time
Throughput speed at
this time
OK
10/01/2019 14:52:35
Add User
OK
10/01/2019 14:19:16
Change Piece Counter
OK
10/01/2019 13:49:42
Remove Text
OK
10/01/2019 13:44:11
Add Text
OK
10/01/2019 10:54:45
Change Mains Language
5.3 Data readout via Ethernet
If an address is assigned to the device in the Settings / System Configuration / IP menu, the
corresponding CSV file of DataMatic can be read out via network connection and saved on the PC.
Caution: A direct connection between the device and PC is not possible. The device needs to be
on a computer network for this.