Van der Ende Groep · Aartsdijkweg 23, 2676 LE, Maasdijk · Tel. 0174 515050
IBAN NL71 RABO 0340341610 · KvK Den Haag 27230471 · Btw-nummer NL8000.78.378.B01 · [email protected] · www.vanderendegroep.nl
Page 16 of 32
4.2.3
Installing the extension
If the greenhouse has multiple screens, an extension will be required. An extension is fitted to two
attachment profiles in the same way as the Airmix.
-
make sure you have the proper tools and equipment:
Quantity
Description
1
Battery impact wrench
1
Torx 25 bit (in impact wrench)
1
8mm socket bit (in impact wrench)
1
13mm open-ended wrench or socket wrench
1
16mm open-ended wrench
1
3mm hex key
-
make sure that the extension can be installed safely; two people are needed for installation,
with one person at height for each lattice truss;
-
what you will need for each extension for each Airmix:
Quantity Description
No. In Figure
5 to 6
Article no. VDEG
1
Airmix model G
15
720052xx
2
Endplate
5
55014310
4
Slide-in bracket for end plate
11
55014380
2
Aluminum attachment profiles
2
580201xx
2
Aluminum cover plate
14
55014330
2
Mounting strips
3
55014320
1
Stainless steel profile connector
17
55014340
1
Extension
30
72005150
2
Stainless steel set screws, hexagon
socket m6x12
4
57023510
10
Stainless steel bolt m8x16
9
57005920
8
Stainless steel fender washer m5
7
57000120
6
Stainless steel fender washer m8
13
57000140
8
Stainless steel washer m8
10
57001140
4
Stainless steel self-locking nut m8
12
57004140
12
Metal screw 4,8x16
6
56033790
17
Metal screw with tapping point 4,8x13
8
56042760
2
Stainless steel
plug ¼’’
16
68032415
-
for installation, see figures in the chapter
“
Installing the
Airmix model G”
-
fit a mounting strip (3) with an M6x10 set screw (4) in the groove of the profile (2), the first
M8 tapped hole 210mm from the end of the profile; do this for two profiles.
-
insert a plug (20) in the end plate; do this for two end plates;
-
attach an end plate (5) to a lattice (1) with two Slide-in brackets (11). Attach the Slide-in
brackets to the end plate with two stainless steel bolts m8x16 (9), four m8 washers (10) and
two self-locking nuts m8 (12).
-
Put two metal screws with tapping point 4,8x13 (6) through each Slide-in bracket (11) and
into the lattice (1);
-
attach a second end plate directly opposite to the first end plate on the next lattice with two
metal screws with tapping point 4,8x13 (6);
-
mount a profile (2) between two end plates with six 4.8x16 self-tapping screws (12);
-
fit two cover plates, lying on each other (7), in the profile;
-
place the extension (19) on the Airmix housing (see Figure 11);
-
mount a second profile between the end plates with six 4.8x16 self-tapping screws;
-
attach the extension with six M8x16 bolts (10) and six M8 fender washers (9);