remove if necessary the metal flakes which are collected on the magnetic oil drain plug (28);
put the oil drain plug (28) back in;
remove the oil filling plug (26);
fill the pump with oil to the marked level;
o
use SAE20/30 or ‘Shell Omala S2 GX 220’ oil.
Make sure the oil is at the marked level on the oil level indicator, to much oil is as harmful as to little
oil.
For pumps fitted with grease nipples on the piston seals;
lubricate the grease nipples every 50 to 100 hours;
use 2cc lubricant per grease nipple.
6.3 Tensioning V-belts
Frequency: every 100 hours:
put the main switch to off;
make the pump pressure free by putting the handle for pressure free start-up (16) in the vertical
position;
remove the transmission guard (3);
loosen the nuts and bolts with which the pump is secured to the mounting plate;
tense the V-belts by turning the tension screw for the V-belts (17);
check the tension on the V-belts;
o
take the V-belt between thumb and index finger;
o
try to rotate the V-belt by rotating your wrist;
the V-belt must be able to rotate about 90 degrees;
line up the pulleys on the pump axle with the pulleys on the motor axle;
o
use the adjusting screw (18);
recheck the tension of the V-belts;
tighten the nuts and bolts with which the pump is secured to the mounting plate;
replace the transmission guard (3);
check whether the transmission guard is correctly connected;
put the main switch to on.
6.4 Leakage
Due to the working temperature (max 40°C ) and/or the quality of the water leakage between
cylinder and piston can occur after 500 to a 1000 hours.
Leakage of water and or oil must be fixed immediately in order to prevent malfunctions and damage.
Leakage of water can result in air entering the suction line, this can cause cavitations.
Leakage of oil can result in the pump running dry on oil and overheating the internal transmissions.