3. Safety instructions
You must read this instruction manual carefully and take the necessary safety measures before
placing and using the Enpres.
The Enpres can only be used for the scope for which the Enpres was designed (see 1.7 and 1.8 for
more information).
The Enpres was designed to function as a high pressure pump in an installation with fluid media.
These fluids can only contain those chemicals to which the materials of the pump are resistant (see
1.3 and 1.5 for more information).
During maintenance and/or reparation of the Enpres the power must be disconnected and the
installation must be made pressure-free. The disconnection of the power must be done with a lockable
main switch (with for example a Padlock). After reparation and/or maintenance always connect
everything and test the installation.
Reparation or connection of the electrical part of the Enpres must be done by professional staff.
Always use a four core wire to connect the electromotor to the power connection. This wire must be
of sufficient quality and diameter, according to relevant decrees.
Always connect the earth wire to the electromotor connection terminal marked with the earth sign.
Make sure the electromotor is connected to a electric group fused at 16 A in combination with a GFCI
of 30 mA.
Check whether the Enpres is pressure free and isolated from the installation after stopping the Enpres.
Follow all installation and safety instructions. Ignoring these instruction van cause serious injury or
damage to people and products.