manualshive.com logo in svg
background image

Valore (“Seller”) and the person or entity that acquires these 

goods from Seller (“Purchaser”) hereby fully agrees to the 

following terms and conditions of the sale: Shipping fees are 

the responsibility of the Purchaser whether freight prepaid 

or freight collect. Seller assumes no responsibility for the 

goods sold to the Purchaser once the goods have left the 

Seller’s premises, including but not limited to, late delivery 

by the moving carrier, or for events caused by any difficulty 

carrier incurs in attempting to fit the goods into the 

Purchaser’s place of business or residence due to size of 

the goods or otherwise Purchaser assumes all responsibility 

for delivery, payment of freight, access, measurement, 

installation, hook-up, wiring, moving and storage of the 

goods. The transportation of all goods is subject to the terms 

and conditions which the moving carrier imposes on 

Purchaser including, but not limited to, additional charges 

imposed per flight of stairs, and/or additional charges 

resulting from the carrier’s inability to safely and/or 

adequately use the building elevator to lift the goods to an 

upper level. Any claim for damages incurred during the 

shipment by the carrier of the goods are insured and 

handled directly with the carrier. Any damages due to 

manufacture defects will be handled directly with Valore, 

subject to the limited warranty.

All sales are final, and unless authorized in writing by the 

Seller, Purchaser may not return the goods, under any 

circumstance. If Purchaser refuses to accept the goods, 

under any circumstance, the Purchaser is liable for the 

return and cost of freight both ways, and if seller does take 

the goods, there may be a restocking fee that of 20% of the 

purchase price of the goods in addition to the freight. 

Purchaser must notify Seller of non-conforming goods 

within seven (7) days of delivery, after which time all goods 

are deemed accepted. If an order has been placed and 

production started, cancellation cost of your order will be 

20% or the purchase price.

The limited warranty does not cover damage due to 

such things as accident, misuse, abuse, mishandling, 

neglect, acts of God, fires, earthquakes, floods, high 

winds, government, war, riot or labor issues defined 

as strikes, lockouts, delay of carrier, unauthorized 

repair, or any other beyond the control of the Seller 

whether similar or dissimilar to the foregoing. Seller is 

not responsible for any damages caused by the 

Purchaser misusing, mishandling or abusing the 

intended the use of the goods. Limited warranty 

applies only inside the Continental U.S. or Canada 

(Alaska, Puerto Rico Hawaii, Yukon, Northwest 

Territories, and Nunavut not included). The limited 

warranty is not transferrable between the US and 

Canada.

The limited warranty is only valid with the provision of 

proof-of-purchase from an authorized retailer of Valore 

branded products.

Seller is not responsible for labor expenses that are 

incurred due to service or installation charges.

Seller is not responsible for incidental or consequential 

damages and there are no warranties, expressed or 

implied, which extend beyond the limited warranty 

described above. The implied warranties of 

merchantability and of fitness for a particular purpose 

are hereby expressly disclaimed. Some states do not 

allow the exclusion of incidental or consequential 

damages, or a waiver of the implied warranties of 

fitness and/or merchantability, so the above limitations 

may not apply to you. This warranty gives you specific 

legal rights and you may have other rights, which vary

from state to state.

LIMITED WARRANTY

Ten (10) years guaranteed from manufacture defects.

Lifetime limited parts warranty on the diverter valve.

Recycling: Most of the materials used to manufacture this 

shower fixture are recyclable. Please dispose of those 

materials properly in accordance to your local state laws. 

Improper disposing of this shower fixture can be harmful to 

the environment.

 

LENGTH OF WARRANTY

If you have questions relating to the use, warranty, 

return, claims and replacement, please call:

Phone: 877-551-0484 

(Monday to Friday 8:30am-5:30pm Pacific)

Email us at [email protected] (24 hour)

For more information, you can visit us at:

www.valoreusa.com

- 16 -

Содержание Effusion

Страница 1: ...anel Installation and User Guide EFFUSION ATTACH YOUR RECEIPT HERE Serial Number Purchase Date If you have questions relating to the use warranty return claims and replacement please call Phone 877 551 0484 Monday to Friday 8 30am 5 30pm Pacific ...

Страница 2: ...IMENSIONS CODE COMPLIANCE FEATURES Read this Installation and User Guide before installing and operating Always take extra care when installing to prevent injury Wear appropriate safety equipment Do not allow children unsupervised use of the shower panel Do not use the shower panel if you are physically impaired or under the influence of alcohol or any substance which may prevent you from properly...

Страница 3: ...be installed to prevent water leakage Manufacturer will not be responsible or liable from any damage which results directly or indirectly from failure to installation of the O Ring Gasket This panel does not include a mixing valve it is intended for use in a shower with an existing mixing valve BEFORE INSTALLATION RECOMMENDED TOOLS FOR INSTALLATION PH 2 5 mm Drill Bit 6mm Electric Drill Wrenches 2...

Страница 4: ... 4 1 8 7 5 4 11 3 2 6 9 6 10 11 12 11 6 15 14 13 15 14 13 16 17 19 20 18 21 ...

Страница 5: ...ASSEMBLY a b 7 12 6 10 11 c d ASSEMBLY 5 1 9 9 9 9 6 9 9 ...

Страница 6: ...d to 4 Two brass extender joints Part 4 are included with this shower panel Test both extender joints to see which joint will provide you a minimum of 5 8 from the wall Use the plumbing tape and wrap the threaded part of the brass extender joint Part 4 on both ends Place the flow regulator Part 17 into the appropriate extender joint Part 4 ensure the flow regulator s direction is right as diagram 4 ...

Страница 7: ...ze of the shower panel The bottom of the template should be above your existing shower valve Recommended that there is a clearance above the valve If the template does not fit within the clearance provided you can mount the panel off center and to the side Installation Template Guide PVC cover is not required if the water outlet is below 33 38 Valve goes below this template Bottom of panel An inst...

Страница 8: ... Hose Part 8 and shear the excess length from the hose Draw a level horizontal line based on the lower edge of the selected hole Shear Connecting the Supply Line Elbow to the main PVC Supply Line 1 Insert the Ring Clamp Part 7 onto the end of PVC Supply Line Part 8 2 Fully insert the grooved end of the Elbow Connector Part 3 into the PVC Supply Line Part 8 3 With a Phillips head screwdriver tighte...

Страница 9: ...es have been drilled insert the provided Anchor Screws Part 15 To ensure the template and your shower panel will be in a completely straight and level position use a level tool against the side of the template guide to make fine adjustments to the template guide s position until fully level Once fully level this will be the final position of the template guide Take a pencil marker and mark the pos...

Страница 10: ... brackets Part 14 using the supplied screws Part 13 For the Positioning Mounting Brackets Part 14 make sure that they are installed with protruding portion facing upward as shown in the drawing 14 12 11 INSTALLATION INSTRUCTIONS 10 14 x2PCS 13 x4PCS PH ...

Страница 11: ... sealant can be applied to seal the gap between the shower panel casing and the shower wall to hold it in place and prevent water from entering behind the panel 1 Peel off the paper backing to the adhesive ring for the Base Plate cover Part 5 2 Place the adhesive side to the wall and apply pressure to secure the Base Plate Cover Part 5 Note Remove all residues to ensure the cover will bond properl...

Страница 12: ...or knob is placed in c When the selector knob is placed in a Shower Head Position a b c When the selector knob is placed in between two operating this will result in a to simultaneous operation of both adjustment spray modes A slight reduction in water pressure may occur due to the shared water flow between the two spray modes Dual Spray Modes When the position knob is placed in the d handshower a...

Страница 13: ...open the set screw access hole 1 Loosen the set screw 1 from the valve stem and pull the knob 2 straight out 2 2 5 mm 3 2 1 Loosen and remove the gland nut 4 4 4 3 13 4 5 1 2 3 3 1 Remove the Diverter valve 5 by pulling it straight out 5 Diverter valve 4 2 5 mm 2 1 1 Diverter valve ...

Страница 14: ...correct position of the knob has been determined place the knob on the valve stem and tighten the set screw 1 Do not overtighten 14 5 Diverter valve Place the Diverter valve 5 into the valve body Note the one pillar on the bottom of the Diverter valve 5 must be aligned with the hole in the rear of the body 2 4 2 Tighten the gland nut 4 Take precaution to avoid scratching the trim plate Do not forc...

Страница 15: ...ing forced into cold water pipe or vice versa when mixer is closed Check valves dirty or leaking Clean check valves exchange if necessary Dirt or sedimentation on valve seat shut off unit damaged Clean or exchange shut off unit Shower drips continuously Modern faucets and shower products utilize a combination of materials to comply with the needs of the market with regard to design and functionali...

Страница 16: ...the purchase price The limited warranty does not cover damage due to such things as accident misuse abuse mishandling neglect acts of God fires earthquakes floods high winds government war riot or labor issues defined as strikes lockouts delay of carrier unauthorized repair or any other beyond the control of the Seller whether similar or dissimilar to the foregoing Seller is not responsible for an...

Отзывы: