Existing Fireplace Preparation

A few points must be considered before inserting the RF24 into an existing fireplace cavity. Generally, modifications to 

the existing fireplace that will compromise its integrity are NOT allowed. Components that are bolted or screwed on, 

such as dampers or baffles, may be removed to accommodate the installation of the RF24 engine. 

Cutting away any 

sheet metal parts off the existing fireplace to accommodate the installation of the RF24 is prohibited

. Check 

with local authorities if in doubt.

Clean Fireplace and Chimney

Have the chimney swept and the fireplace cavity including ash dumps and clean-outs cleaned before installing the 

RF24 heater and vent liners. Any creosote or soot residue remaining in the fireplace cavity chimney or clean-out may 

cause odors or stains once the RF24 insert is installed. Consult with chimney sweep for information on how best to 

clean.

Existing Dampers

Factory-built, zero clearance fireplaces will require the damper to be removed in order to install the vent liners. These 

dampers are usually bolted into place. Dampers in masonry fireplaces must be fixed open and may remain in place.

Ash Retaining Curbs

Some fireplaces (particularly factory-built) have a raised curb at the front edge to retain ashes. Check the dimensions 

carefully to ensure the RF24 engine will fit behind any raised curb (some curbs may be removed separately from the 

refractory base). The fret retainers allow for some vertical adjustment of the cast iron fret should the fret need to sit on 

top of the curb, otherwise the fret will need to be eliminated or adequate room provided behind the curb.

Gas Line Routing

Plan the routing of the gas line before proceeding. Utilize the existing hole for the gas line. If the factory-built fireplace 

has no access hole, carefully drill an access hole of 1-1/2 inch (38 mm) or less through the lower sides or bottom of the 

firebox. The access hole must be plugged with non-combustible insulation after the gas supply line has been installed. 

See illustration in 

Dimensions

 section for detailed location of gas inlet. Also, take into consideration whether or not a 

fan or shut-off valve will interfere when planning the routing of the gas line.

Existing Glass Doors and Wire Screens

Existing glass doors must be permanently removed

 prior to installing the RF24 insert. Existing wire fire screens 

may remain in place or new ones may be added. The RF24 has been tested and approved to operate with wire fire 

screens in the 

closed

 or 

open

 positions.

Combustible Mantels

Combustible mantel clearances must conform to those required for the original solid-fuel fireplace into which the RF24 

is being installed.

Paint Existing Refractory Liners

It may be desirable, for visual reasons, to paint the existing refractory liners in black to blend in with the RF24 insert 

once installed.

Attach Warning Label to Existing Fireplace 

(label supplied loose with RF24 heater)

Attach the label “This fireplace has been converted...” 

to the existing fireplace

 using screws or other mechanical 

means and store any removed parts in the back of the existing fireplace for future use.

Содержание Retrofire F24BN

Страница 1: ...ance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfireplaces com Do not store or use gasoline or other flammable...

Страница 2: ...dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time of prin...

Страница 3: ...pliance Preparation 10 Firebox Installation 11 Ceramic Fuel Bed Installation 13 Window Refitting 14 Remote Control Installation 15 Operation Check and Aeration Adjustment 15 Vent Check 16 Cast Iron Fr...

Страница 4: ...peration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appli...

Страница 5: ...adian Electrical Code CSA C22 1 Ratings High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level F...

Страница 6: ...nsert is being installed NOTE The glass front and hearth are very hot Existing wire mesh screens or free standing hearth mounted mesh screens may be used in front of the RF24 insert to help minimize t...

Страница 7: ...configurations refer to the venting tables in the National Fuel Gas Code Z223 1 or the Natural Gas and Propane Installation Code B149 1 Approved Termination Required Max 16 offset if vent height is m...

Страница 8: ...cal adjustment of the cast iron fret should the fret need to sit on top of the curb otherwise the fret will need to be eliminated or adequate room provided behind the curb Gas Line Routing Plan the ro...

Страница 9: ...that system at test pressures in excess of psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of...

Страница 10: ...r Unpack appliance Remove window Remove log pack from firebox Strip firebox down by removing Burner module 4 screws Vent plate Support Legs 2 screws per leg required when inserting into small fireplac...

Страница 11: ...imney after the firebox is installed Thread thumbscrews into Support Leg Raise left hand side of firebox and slip LH Support Leg Under Fasten with 2 bolts as indicated Thread thumbscrews into Support...

Страница 12: ...ns section Reinstall the Top Baffle if removed Install Top Convection Baffle Position the firebox as far back as possible within the existing fireplace to allow ample space at the front for the fret P...

Страница 13: ...rn Side Brick in front of Rear Brick Rear Brick Left Brick Rest Brick on Rear Log Support Rear Brick Rear Brick Left Brick Right Brick Install the Ceramic Log Set Carefully remove the ceramic logs fro...

Страница 14: ...ebox and fasten the bottom two spring loaded bolts by pushing in and turning 90 degrees If broken the glass pane may only be replaced as a complete window assembly unit as supplied by the manufacturer...

Страница 15: ...ector CAUTION DO NOT PUT BATTERIES IN THE REMOTE CONTROL RECEIVER until the wires are connected to the burner control unit as short circuit could result in the destruction of the electrical components...

Страница 16: ...signed to maintain the required space in front of the window to allow the window to move and relieve during a hard start It is very important to ensure the area in front of the window is kept clear at...

Страница 17: ...is manual WARNING DO NOT TOUCH THE GLASS WHILE IT IS HOT Let the fireplace cool first before cleaning it CAUTION Your fireplace becomes very hot when operating Avoid placing decorating objects sensiti...

Страница 18: ...30 minutes In the event that the safety switch is activated again contact a qualified service technician for inspection Should the safety switch require replacement only use parts supplied by Miles In...

Страница 19: ...f Finally decide what time you want it to come back on and off in the afternoon or evening For the first few times you set the timer it s handy to write these times down 2 Set the temperature just as...

Страница 20: ...nd chimneys or 4 dia type B vent with zero clearance kit option Circulating Fan 555CFK Circulating Fan Kit thermally actuated variable Speed with 6 0 c w grounded cordset Conversion Kits RA24NK Conver...

Страница 21: ...y information above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in pa...

Страница 22: ...n for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not c...

Страница 23: ...e nuts 4000600 27 Tube Nut 220K558 28 Valve Mount 4000141 29a 190 Series Pilot Assy NG 4000727 29b 190 Series Pilot Assy LPG 4000728 30 Electrode Nut 720A200 31 Interrupter Block 4000202 32 Pilot Brac...

Страница 24: ...24 Parts...

Страница 25: ...G natural gas LPG propane Serial No Fret code description e g RA24TB Traditional Black Fret Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Address Sto...

Страница 26: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: