Warranty

1. Extended Warranty Coverage

For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the 

initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or 

workmanship under normal conditions of use and service:

2. Two-Year Parts Warranty 

In addition, for two (2) years from the date of purchase, the Company, at its option, can repair or exchange all parts and 

components not listed above but that are found to have a 

bona fide

 defect in material or workmanship under normal conditions of 

use.

3. Conditions and Limitations

a)  The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase.

b)  Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s 

installation instructions.

c)  This warranty is void where installation of the unit does not conform to all applicable codes including national and local gas 

appliance installation codes and building and fire codes.

d)  The owner must comply with all operating instructions.

e)  The Company is not responsible for the labor costs to remove defective parts or re-install repaired or replacement parts.

f)  The first purchaser or user of the unit will be responsible for any shipping charges for replacement parts as well as travel time 

incurred by the dealer to perform the warranty work.

g)  This warranty applies to non-commercial use and service and is void if it is apparent that there is abuse, misuse, alteration, 

improper installation, accident or lack of maintenance to the unit.

h)  This warranty does not cover damage to the unit through:

i) 

Improper installation, operational or environmental conditions.

ii)  Inadequate ventilation in the area or competition for air from other household equipment or appliances.

iii)  Damage due to chemicals, dampness, condensation, or sulphur in the fuel supply lines which exceeds industry 

standards.

i)  This warranty does not cover glass, log breakage or damage to the unit while in transit.

j)  The Company does not allow anyone to extend, alter or modify this warranty and assumes no responsibility for direct, indirect 

or consequential damages caused by the unit. State or provincial laws where the first purchaser or user resides may provide 

specific rights to extend this warranty and, if so, the Company’s sole obligation under this warranty is to provide labor and/or 

materials in accordance with those laws.

4. Discharge of Liability

After two (2) years from the date of purchase, the Company may, at its option, fully discharge all obligations under this warranty by 

paying to the first purchaser/user the wholesale price of any defective parts.

5. No Other Warranty

All obligations to repair this unit are defined in this warranty. Some states or provinces may specifically mandate additional 

warranties on the part of manufacturers, but in the absence of such specific legislation, there is no other warranty or obligation 

expressed or implied.

Part or Component

Defect Covered

Maximum Warranty Period

Exterior steel casing

Corrosion

10 years

Glass

Loss of structural integrity

10 years

Cast iron parts

Corrosion

10 years

Firebox and heat exchanger

Corrosion (but not discoloration) causing 

loss of structural integrity

10 years

WARR

ANT

Y P

ROG

RAM

WARR

ANT

Y P

ROG

RAM

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

If  you  have  a  problem  with  this  unit,  please  contact  your  dealer  or 

supplier immediately. Under no circumstances should you attempt to 

service the unit in any way by yourself. The warranties in paragraphs 

1 and 2 are provided only to the first purchaser/user of this unit, are 

not  transferable  and  are  subject  to  the  conditions  and  limitations  in 

paragraphs  3,  4  and  5.  Please  review  the  conditions  and  limitations 

carefully and strictly follow their requirements.

Содержание Retrofire F24BN

Страница 1: ...ance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfireplaces com Do not store or use gasoline or other flammable...

Страница 2: ...dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time of prin...

Страница 3: ...pliance Preparation 10 Firebox Installation 11 Ceramic Fuel Bed Installation 13 Window Refitting 14 Remote Control Installation 15 Operation Check and Aeration Adjustment 15 Vent Check 16 Cast Iron Fr...

Страница 4: ...peration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appli...

Страница 5: ...adian Electrical Code CSA C22 1 Ratings High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level F...

Страница 6: ...nsert is being installed NOTE The glass front and hearth are very hot Existing wire mesh screens or free standing hearth mounted mesh screens may be used in front of the RF24 insert to help minimize t...

Страница 7: ...configurations refer to the venting tables in the National Fuel Gas Code Z223 1 or the Natural Gas and Propane Installation Code B149 1 Approved Termination Required Max 16 offset if vent height is m...

Страница 8: ...cal adjustment of the cast iron fret should the fret need to sit on top of the curb otherwise the fret will need to be eliminated or adequate room provided behind the curb Gas Line Routing Plan the ro...

Страница 9: ...that system at test pressures in excess of psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of...

Страница 10: ...r Unpack appliance Remove window Remove log pack from firebox Strip firebox down by removing Burner module 4 screws Vent plate Support Legs 2 screws per leg required when inserting into small fireplac...

Страница 11: ...imney after the firebox is installed Thread thumbscrews into Support Leg Raise left hand side of firebox and slip LH Support Leg Under Fasten with 2 bolts as indicated Thread thumbscrews into Support...

Страница 12: ...ns section Reinstall the Top Baffle if removed Install Top Convection Baffle Position the firebox as far back as possible within the existing fireplace to allow ample space at the front for the fret P...

Страница 13: ...rn Side Brick in front of Rear Brick Rear Brick Left Brick Rest Brick on Rear Log Support Rear Brick Rear Brick Left Brick Right Brick Install the Ceramic Log Set Carefully remove the ceramic logs fro...

Страница 14: ...ebox and fasten the bottom two spring loaded bolts by pushing in and turning 90 degrees If broken the glass pane may only be replaced as a complete window assembly unit as supplied by the manufacturer...

Страница 15: ...ector CAUTION DO NOT PUT BATTERIES IN THE REMOTE CONTROL RECEIVER until the wires are connected to the burner control unit as short circuit could result in the destruction of the electrical components...

Страница 16: ...signed to maintain the required space in front of the window to allow the window to move and relieve during a hard start It is very important to ensure the area in front of the window is kept clear at...

Страница 17: ...is manual WARNING DO NOT TOUCH THE GLASS WHILE IT IS HOT Let the fireplace cool first before cleaning it CAUTION Your fireplace becomes very hot when operating Avoid placing decorating objects sensiti...

Страница 18: ...30 minutes In the event that the safety switch is activated again contact a qualified service technician for inspection Should the safety switch require replacement only use parts supplied by Miles In...

Страница 19: ...f Finally decide what time you want it to come back on and off in the afternoon or evening For the first few times you set the timer it s handy to write these times down 2 Set the temperature just as...

Страница 20: ...nd chimneys or 4 dia type B vent with zero clearance kit option Circulating Fan 555CFK Circulating Fan Kit thermally actuated variable Speed with 6 0 c w grounded cordset Conversion Kits RA24NK Conver...

Страница 21: ...y information above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in pa...

Страница 22: ...n for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not c...

Страница 23: ...e nuts 4000600 27 Tube Nut 220K558 28 Valve Mount 4000141 29a 190 Series Pilot Assy NG 4000727 29b 190 Series Pilot Assy LPG 4000728 30 Electrode Nut 720A200 31 Interrupter Block 4000202 32 Pilot Brac...

Страница 24: ...24 Parts...

Страница 25: ...G natural gas LPG propane Serial No Fret code description e g RA24TB Traditional Black Fret Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Address Sto...

Страница 26: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: