Valor CHURCHILL 32-810-58 Скачать руководство пользователя страница 5

OWNER’S GUIDE

Page 5

 

Provide the following clearance for combustible projections up to a depth of
178mm (Measured from the rear fixing plane of the fire). A minimum clearance
of 75mm should be maintained at the left and right side of the fire. This is
measured from the extreme side of the case.  This will allow easy access to the
control knob and knurled nuts for removal of the outer case. This clearance is
mandatory for temperature requirements.

 

Provide the following clearances for combustible projections beyond 178mm
(Measured from the rear fixing plane of the fire). A minimum clearance of
100mm should be maintained at the left and right side of the fire. This is
measured from the extreme side of the case. This clearance is mandatory for
temperature requirements.

 

Provide the following clearances for non-combustible projections. (Measured
from the rear fixing plane of the fire). A minimum clearance of 75mm should be
maintained at the left and right side of the fire. This is measured from the extreme
side of the case. This will allow easy access to the control knob and knurled nuts
for removal of the outer case

 

Provide a suitable guard that complies with BS 6539 or 6778 for the protection of
young children, the elderly and the infirm. Such a guard is also recommended for
the protection of pet animals. 

Although this fire conforms to all the applicable

standards, it is a heating appliance and certain parts of its surface will become
hot.

 

Wait three minutes before attempting to relight if the fire is switched off or the
flames are extinguished for any reason. 

Your fire is fitted with a safety device

that will automatically shut off the gas supply to the fire if, for any reason, the
flames go out.

 

Get advice about the suitability of any wall covering near your fire. Soft wall
coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily
affected by heat. They may, therefore, scorch or become discoloured when close
to a heating appliance. Please bear this in mind whenever you are considering
redecorating.

 

Keep the flue terminal on the outside wall free from all obstructions and
blockages.

DON’T

H

 

Hang clothing, towels or any other fabrics over the fire.

H

 

Use the fire without the glass window panel in position or with damaged glass.

H

 

Add any additional coals on to the ceramic fuel pieces supplied with the fire.
This could cause a safety hazard.

Содержание CHURCHILL 32-810-58

Страница 1: ...gas fire Please read thoroughly before using and keep for future reference For Service Phone 0845 960 5040 Manufactured exclusively for British Gas Scottish Gas by Valor Heating Wood Lane Erdington Bi...

Страница 2: ...nstitute The Highest Standards The manufacturer is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The man...

Страница 3: ...10 3 3 Replacing the coal pieces 11 4 SERVICING MAINTENANCE 15 C U S T O M E R C A R E This gas fire is designed to meet the most stringent quality performance and safety requirements to provide our...

Страница 4: ...Kingdom installation must be in accordance with the latest edition of the Gas Safety installation use Regulations In the Republic of Ireland installation must be in accordance with all national and lo...

Страница 5: ...ts for removal of the outer case Provide a suitable guard that complies with BS 6539 or 6778 for the protection of young children the elderly and the infirm Such a guard is also recommended for the pr...

Страница 6: ...o clean the bright metal interior of the firebox with metal polish or other abrasives After a little time the firebox will colour This is quite normal Please Note As with all windows the glass may nee...

Страница 7: ...re has a maximum gas input of 4 9 kW Gross The fire has a maximum heat output of 3 54 kW Gross The fire has a minimum gas input of 2 2 kW Gross The fire has a minimum heat output of 1 59 kW Gross The...

Страница 8: ...onsecutive sparks to occur which should ignite the pilot gas A click should be heard while turning each time a spark is generated The pilot flame can be seen by looking through the gap at the front of...

Страница 9: ...trol knob partially turn clockwise to IGN and release the knob If any resistance is felt at position 1 when turning release the downward pressure on the knob before continuing to turn 2 5 2 To turn th...

Страница 10: ...aced Secure with the 12 wing nuts tightening them evenly 3 1 6 Replace the case front 3 2 Cleaning the coal pieces 3 2 1 This product uses a fuel effect piece containing Refractory Ceramic Fibres RCF...

Страница 11: ...of cardboard or similar 3 2 6 Carefully clean the upper and lower surfaces of the coals with a soft brush or vacuum using a soft brush attachment 3 2 7 Replace the coal pieces as described below 3 3...

Страница 12: ...the right side See figure 6 3 3 3 Place the front left coal embossed C underneath in position at the side of the first coal The flat bottom front face of the coal should rest on the metal ledge immed...

Страница 13: ...OWNER S GUIDE Page 13 3 3 5 Place the rear right coal embossed D underneath in position as shown in figure 8 Figure 8 Rear right coal D Location...

Страница 14: ...embossed E underneath shown in figure 9 3 3 7 Replace the window unit ensuring that the seal around the frame is not damaged or misplaced Secure with the 12 wing nuts tightening them evenly 3 3 8 Repl...

Страница 15: ...safety at least every twelve months If you require your fire to be serviced please contact British Gas or Scottish Gas Telephone 0845 960 5040 and please quote the following details which can be found...