Valor Adorn 640 Скачать руководство пользователя страница 46

INSTALLER’S GUIDE

Page 46

 Figure 64. Thermocouple interrupter block

apply tension to the microswitch leads.

7.

 

Remove the two fixing screws that

attach the generator unit to the support
bracket. The igniter generator can now
be removed. (see figure 63)

8.

 

Remove the two leads to the switch

and remove the spark lead. If
necessary, mark them to ensure that
they are replaced on to the correct
terminals.

9.

 

Replace the generator

10.

 

Refit in the reverse order.

16.9

 

To Remove the Thermocouple

Interrupter Block

See figure 64.

1.

 

Remove the bottom front and fire

front castings and the front surround  -
See section 16.3.

2.

 

 Detach the thermocouple from the

interrupter block by unscrewing the
thermocouple nut.

3.

 

Detach the two microswitch leads

from the interrupter block.

4.

 

Remove the interrupter block by

unscrewing from the gas
shut-off tap.

5.

 

Refit in the reverse

order. If the microswitch
leads cannot be easily
attached to the interrupter
block when it is fully
tightened to the gas shut-
off tap, slacken it and
rotate to allow the leads to
be fitted. Retighten making
sure that the leads remain
in place in the interrupter
block. Fit and tighten the

Figure 63. Removal of Electronic
Generator.

Содержание Adorn 640

Страница 1: ...these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our Valor Technical Helpline will be pleas...

Страница 2: ...hest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered compan...

Страница 3: ...t the fire If for any reason this weight is considered too heavy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is b...

Страница 4: ...4 2 Check For Spillage 39 14 3 Flame Supervision Spillage Monitoring System 39 15 FINAL REVIEW 41 16 SERVICING PARTS REPLACEMENT 42 16 1 Checking the aeration setting of the burner 42 16 2 To Remove t...

Страница 5: ...ardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when handling these articles but we recommend you follow the nor...

Страница 6: ...to recognised standards In the United Kingdom the installation must also be in accordance with All the relevant parts of local regulations All relevant codes of practice The relevant parts of the cur...

Страница 7: ...rth should be installed as in figure 1 Icon firefront If when using the Icon firefront a Hearth is not fitted the fire must be installed so that the distance from the base of the fireplace opening in...

Страница 8: ...the fireplace opening is greater than the acceptable dimensions given in this guide do not use the back of a fire surround or marble to reduce the opening This may cause cracking of the surround back...

Страница 9: ...pt clean prior to installation All flues should be inspected for soundness and freedom from blockages 2 9 If the fireplace opening is an underfloor draught type it must be sealed to stop any draughts...

Страница 10: ...INSTALLER S GUIDE Page 10 ADORN MODEL ONLY Graph 1 Combustible shelf clearances for ADORN model only VISAGE AND ICON MODELS ONLY Graph 2 Combustible shelf clearances for VISAGE and ICON models only...

Страница 11: ...in any room that contains a bath or shower or where steam is regularly present 2 15 An extractor fan may only be used in the same room as this appliance or in any area from which ventilation for the...

Страница 12: ...ombustible material or any other combustible surface which projects beyond the front of the appliance is shown in figure 5 A 10mm access clearance from a non combustible surface is necessary at the le...

Страница 13: ...INSTALLER S GUIDE Page 13 ADORN VISAGE Figure 5 Appliance dimensions Continued on next page...

Страница 14: ...rictor 2 Screws For Fireback spacing brackets 2 Screws For Rear Ceramic wall support bracket 1 Ceramic back wall 1 Pair of ceramic side walls 1 Left Hand Front coal 1 Right Hand Front coal 1 Main coal...

Страница 15: ...Front contains 2 Surround Securing Brackets 1 Fire front surround with sliding control 1 Fire front casting 1 Bottom front cover casting 1 Canopy shield 3 Tapping screws for canopy shield 4 Machine s...

Страница 16: ...INSTALLER S GUIDE Page 16 Figure 6 Pack contents...

Страница 17: ...fitted against a wall with combustible cladding the cladding must be removed from the area covered by the outer surround The cladding must also not touch the surround See figure 4 We suggest that the...

Страница 18: ...0mm layer of mineral wool or equivalent insulation See figure 2 4 2 Fireplace Flue Pull Close all doors and windows in the room in which the appliance is to be installed After confirming with a match...

Страница 19: ...see figure 8 The positive terminal is to the bottom as you insert Depress the slider as far as it will go This should close the ignition circuit Sparks should be seen tracking from the electrode pin t...

Страница 20: ...box must be kept away from the area which will be taken by the convection box when it is installed See figure 7 Note that the centre of the appliance inlet elbow is 25mm above the fireplace floor The...

Страница 21: ...upply pipe is to pass through it 4 The appliance is supplied with two fireback spacers Do not fit the fireback spacers if the fire is to be installed into a precast or clay flue block system as in sec...

Страница 22: ...ppliance and is fixed with three screws See figure 14 7 There is a length of self adhesive foam seal supplied with the fire This will need to be fitted to the outer rear edges of the side and top flan...

Страница 23: ...rews If necessary make sound with a suitable cement 2 Place the convection box centrally in the fireplace in the position in which it is to be permanently installed If a concealed connection is being...

Страница 24: ...should be equidistant each side of the centre line of the fireplace to ensure that the appliance finishes centrally in the opening when tension is applied to the cables 3 Insert a fibre plug into each...

Страница 25: ...ing so that it is sealed against the fireplace front surround 8 Drill a hole into the fireplace floor through each of the two holes in the base of the convection box using a no 12 masonry drill See fi...

Страница 26: ...push the cable retainers back against the V brackets Again tighten the screws in the retainers and apply tension to the cables by turning the hexagonal adjusters clockwise as far as possible 14 Undern...

Страница 27: ...lose the ignition circuit and simultaneously open the gas tap allowing the gas to flow to the pilot Wait a few seconds while the air is purged The electronically generated sparks should light the pilo...

Страница 28: ...a pressure gauge at the test point The test point is on the pipe situated below the bottom right corner of the burner unit See figure 25 Check the pressure with the appliance alight and set at maximum...

Страница 29: ...flat against the back face of the burner compartment See figure 26 3 Remove four screws from the spillage plate sides See figure 27 4 Remove the spillage plate by lifting it forward 5 Fit the ceramic...

Страница 30: ...lly over the retaining brackets on the convection box See figure 28 If the inlet pipe runs along the front of the fireplace the bottom of the casting will have to be swung forwards to clear the pipe w...

Страница 31: ...ackets See figure 32 Swing the bottom control linking bar towards the centre of the fire to clear the right side of the surround Fix the bottom of the surround unit to the convection box with two scre...

Страница 32: ...rackets See figure 35 Installer Note that the small round holes in the burner plaques that will be covered by the base coal are not gas burner ports They are simply a consequence of the plaque manufac...

Страница 33: ...t 90 to the rear of the firebox 7 Hold coal A upright with the arrow pointing to the top Locate coal A as shown in figure 37 8 Locate coals B to E so that they are firmly seated in the valleys in the...

Страница 34: ...Hold coal E upright with the arrow pointing to the top Locate coal E as shown in figure 41 13 Hold coal F upright with the arrow pointing to the top Locate coal F as shown in figure 42 14 This will c...

Страница 35: ...th the arrow pointing to the top Locate coal G as shown in figure 43 17 Hold coal H upright with the arrow pointing to the top Locate coal H as shown in figure 44 18 Hold coal I upright with the arrow...

Страница 36: ...l J as shown in figure 46 20 Hold coal K upright with the arrow pointing to the top Locate coal K as shown in figure 47 21 Hold coal L upright with the arrow pointing to the top Locate coal L as shown...

Страница 37: ...surround If the screw heads do not project enough or project too far the screws can be adjusted Lower the casting so that it rests on the hearth see figure 49 13 2 2 Place the bottom front cover casti...

Страница 38: ...ain in this position to ignite the pilot The burner should ignite at its lowest setting within 4 seconds of the pilot igniting Keep at this position for a further 10 seconds to allow the pilot flame t...

Страница 39: ...e fireplace surround If the sealing is satisfactory but the appliance is installed with the flue restrictor see section 7 point 8 remove the restrictor reseal the appliance and retest If smoke is stil...

Страница 40: ...n electromagnetic valve shutting off the gas supply through the tap The valve is located in the body of the tap The valve should operate within 60 seconds of the pilot going out If the valve does not...

Страница 41: ...als must be added over and above those supplied with the appliance and that any replacements must only be the authorised spares Warn that ignoring this advice could cause incomplete clearance of the p...

Страница 42: ...a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire When replacing these articles we recommend that the replaced items are not b...

Страница 43: ...the appliance 16 2 To Remove the Ignition Microswitch See figures 54 55 The ignition microswitch is stamped V4NT9C4YC 1 Remove the bottom front cover and the fire front casting 2 Detach the microswitc...

Страница 44: ...g 2 Detach the control linking bar from the control pivot bracket by removing the knurled screw which joins the control linking bar to the control pivot unit See figure 58 3 Remove the two screws secu...

Страница 45: ...oid straining the pipework and disconnect the appliance from the elbow 4 Detach the burner unit from the convection box by removing two screws See figure 61 5 Replace in the reverse order 16 8 To Remo...

Страница 46: ...pter Block See figure 64 1 Remove the bottom front and fire front castings and the front surround See section 16 3 2 Detach the thermocouple from the interrupter block by unscrewing the thermocouple n...

Страница 47: ...irst screw securing the dust cage to the pilot unit burner Carefully remove the dust cage and place aside See figure 65 13 Remove the second screw securing the pilot unit to the burner Remove the pilo...

Страница 48: ...t end of the old tap and fit to the replacement tap Refit in the reverse order When refitting make sure that the tap spindle is in the correct relationship relative to the control pivot bracket Rotate...

Страница 49: ...e front mounting bracket and remove the flow rate controller 10 Refit in the reverse order 16 13To Remove the Main Burner Injector See figure 68 1 Remove the burner unit See section 16 6 2 If lying th...

Страница 50: ...the gasket ends inwards to form a dividing gasket between the plaques 8 Place the new left hand plaque in position The left side of the plaque must touch the inside edge of the retaining flange at the...

Страница 51: ...f installation instructions remove the screws If the fire retention is as method 2 See section 8 2 of installation instructions slacken the hexagonal adjusters on the cable retainers and unscrew the t...

Страница 52: ...INSTALLER S GUIDE Page 52 1 7 S H O R T L I S T O F S P A R E S...

Страница 53: ...A249 Pilot unit For Propane Gas Appliances 720A300 G Injector Bray cat 18U size 420 For Natural Gas Appliances 1 720A072 Injector Stereomatic size 170 and carrier For Propane Gas Appliances 3002350 H...

Отзывы: