INSTALLER’S GUIDE
Page 22
5.
This appliance is supplied with a
flue restrictor for use where the flue
draught is excessive. The restrictor
must NOT be fitted where a precast
flue or a flue liner is used. For all other
installations the restrictor should be
fitted. There may however, be certain
exceptional circumstances where
fitting the restrictor causes the fire to
fail the spillage test. In such cases the
restrictor will have to be removed.
After removal conduct the
spillage check again.
6.
The restrictor is packed
loose with the appliance and is
fixed with three screws. See
figure 14.
7.
There is a length of self
adhesive foam seal supplied with
the fire. This will need to be
fitted to the outer rear edges of
the side and top flanges of the
convection box. Cut a 485mm
length of foam seal. Be careful
not to stretch the seal when
measuring. Remove the
protective backing from the
foam seal and fit this to the rear
of the top flange (See figure 15).
Cut two 580mm lengths. Fit
these to the rear outer edges of
the side flanges. Ensure that
there is no gap between the foam
seals where they meet at the top
flange (See figure 15)
8.
Fit the Canopy shield to the convected air outlet using three self-tapping screws.
Figure 15. Fitting the foam seal
Figure 14. Flue Restrictor